Yaskawa MP2200 Machine Controller User Manual

Page 140

Advertising
background image

4 Motion Parameters

4.3.1 Motion Fixed Parameter Details

4-20

( 5 ) Infinite Axis Reset Position

( 6 ) Software Limits

The software limit function is enabled only after completing a Zero Point Return or Zero Point
Setting operation (i.e., when IB††0C5 is ON). For details, refer to 9.3 Software Limit Function.

No. 9

Gear Ratio [LOAD]

Setting Range

Setting Unit

Default Value

1 to 65535

rev (revolutions)

1

Same as for No. 8.

(cont’d)

No. 10

Maximum Value of Rotary Counter (POSMAX)

Setting Range

Setting Unit

Default Value

1 to 2

31

−1

Reference unit

360000

Set the reset position when an infinite length axis is set.
Enabled when bit 0 of the Function Selection 1 (fixed parameter 1) is set to infinite axis.

The position data for infinite axes is controlled in the range from 0 to POSMAX.

POSMAX

0

Position

Forward

rotation

Reverse

rotation

No. 12

Forward Software Limit

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

Reference unit

2

31

−1

Set the position to be detected for the software limit in the positive direction at the MP2200/MP2300.
If an axis attempts to move in the positive direction past the position set here, a positive software limit alarm (IB††043) will
occur.

No. 14

Reverse Software Limit

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

Reference unit

−2

31

Set the position to be detected for the software limit in the negative direction at the MP2200/MP2300.
If an axis attempts to move in the negative direction past the position set here, a negative software limit alarm (IB††044) will
occur.

Bit 1, 0: Disabled

1: Enabled

Negative
Software Limit

Positive
Software Limit

Range of machine movement

No. 1: Function Selection 1

Bit 2, 0: Disabled

1: Enabled

No. 1: Function Selection 1