5.2.12 Change Filter Type (CHG_FILTER)

The CHG_FILTER command enables the current setting of the Filter Type (motion setting parameter
OW††03) for execution of the following motion commands: POSING, EX_POSING, ZRET,
INTERPOLATE, LATCH, FEED, and STEP.

Always execute CHG_FILTER command after changing the setting of OW††03.

( 1 ) Operating Procedure

( 2 ) Holding and Aborting

The Command Pause bit (OB††090) and the Command Abort bit (OB††091) cannot be used.

IMPORTANT

No.

Execution Conditions

Confirmation Method

1

There are no alarms.

Both IL††02 and IL††04 are 0.

2

The Servo ON condition.

IB††001 is ON.

3

Pulse distribution has been completed for the
SERVOPACK.

IB††0C0 is ON.

4

Motion command execution has been completed.

IW††08 is 0 and IB††090 is OFF.

Execute the

CHG_FILTER motion command.

• Set OW††08 to 13.

• Select one of the following filters:

1.No filter
2.Exponential acceleration/deceleration
3.S-curve acceleration/deceleration (Moving average filter)

• The Command Pause (OB††090) cannot be used.
• The Command Abort (OB††091) cannot be used.

The Acceleration/Deceleration Filter Type is
enabled.

• IW††08 will be 13 during command

execution.

• IB††090 will be ON during command

execution.

Command Execution Completed.

• IW††08 will be 13 and IB††090 will be

OFF.

Execute NOP motion command.

• Set OW††08 to 0.