5 Motion Commands

5.2.6 JOG Operation (FEED)

5-66

( 5 ) Timing Charts

[ a ] Normal Execution

[ b ] Execution when Aborted

IB††0C0

Distribution
Completed

Turns ON when pulse distribution has been completed for the move command.
Turns OFF during execution of a move command.

IB††0C1

Positioning
Completed

Turns ON when pulse distribution has been completed and the current position is
within the Positioning Completed Width. OFF in all other cases.

IB††0C3

Position Proximity

The operation depends on the setting of the Positioning Completed Width 2 (setting
parameter OL††20).

OL††20 = 0: Turns ON when pulse distribution has been completed (DEN = ON).
OL††20

≠ 0: Turns ON when MPOS - APOS< Position Proximity Setting even

if pulse distribution has not been completed.

OFF in all other cases.

(cont’d)

Parameter

Name

Monitor Contents

OW

08 = 7 (FEED)

IW

08 = 7 (FEED)

IB

090 (BUSY)

IB

098 (COMPLETE)

IB

093 (FAIL)

IB

0C0 (DEN)

1 scan

1 scan

OB

091 (ABORT)

OW

08 = 7 (FEED)

IW

08 = 7 (FEED)

IB

090 (BUSY)

IB

098 (COMPLETE)

IB

093 (FAIL)

IB

0C0 (DEN)