4.2 Motion Parameter Lists

4-15

IL††26

Primary Lag Monitor

Unit is according to OW††03, bits 0 to 3 (Speed Unit).
Stores IL††24

− (Output from primary delay element).

Yes

IL††28

Position Loop Output
Monitor

Unit is according to OW††03, bits 0 to 3 (Speed Unit).

Yes

IL††2A

Reserved

IW††2C

Network Servo Status

Bit 0: Alarm Occurred (ALM)
Bit 1: Warning Occurred (WARNING)
Bit 2: Command Ready (CMDRDY)
Bit 3: Servo ON (SVON)
Bit 4: Main Power ON (PON)
Bit 5: Machine Lock (MLOCK)
Bit 6: Zero Point Position (ZPOINT)
Bit 7: Positioning Completed (PSET)/
Speed Coincidence (V-CMP)
Bit 8: Distribution Completed (DEN)/Zero Speed (ZSPD)
Bit 9: Torque Being Limited (T_LIM)
Bit A: Latch Completed (L_CMP)
Bit B:Position Proximity (NEAR)/Speed Limit (V_LIM)
Bit C: Positive Soft Limit (Positive Software Limit) (P_SOT)
Bit D: Negative Soft Limit (Negative Software Limit) (N_SOT)

Yes

Bits E to F: Reserved

IW††2D

Servo Alarm Code

Stores the alarm code from the SERVOPACK.

Yes

IW††2E

Network Servo I/O Monitor

Bit 0: Positive Drive Prohibited Input (P_OT)
Bit 1: Negative Drive Prohibited Input (N_OT)
Bit 2: Zero Point Return Deceleration Limit Switch Input (DEC)
Bit 3: Encoder Phase-A Input (PA)
Bit 4: Encoder Phase-B Input (PB)
Bit 5: Encoder Phase-C Input (PC)
Bit 6: First External Latch Input (EXT1)
Bit 7: Second External Latch Input (EXT2)
Bit 8: Third External Latch Input (EXT3)
Bit 9: Brake Output (BRK)
Bit A: Reserved
Bit B: Reserved
Bit C: CN1 input signal (IO12)
Bit D: CN1 input signal (IO13)
Bit E: CN1 input signal (IO14)
Bit F: CN1 input signal (IO15)

Yes

IW††2F

Network Servo User Monitor
Information

Bits 0 to 3: Monitor 1
Bits 4 to 7: Monitor 2
Bits 8 to B: Monitor 3
Bits C to F: Monitor 4

Yes

IW††30

Servo User Monitor 2

Stores the result of the selected monitor.

Yes

IW††32

Servo User Monitor

3

Stores the result of the selected monitor.

Yes

W††34

Servo User Monitor 4

Stores the result of the selected monitor.

Yes

IW††36

Servo Constant Number

Stores the number of the parameter being processed.

Yes

IW††37

Auxiliary Servo User
Constant Number

Stores the number of the parameter being processed.

IW††38

Servo User Constant

Stores the data of the parameter being read.

Yes

IW††3A

Auxiliary Servo User
Constant

Stores the data of the parameter being read.

Yes

IW††3F

Motor Type

Stores the type of motor actually connected.

0: Rotary motor
1: Linear motor

Yes

IL††40

Feedback Speed

Unit is according to OW††03, bits 0 to 3 (Speed Unit).

Yes

Yes

Yes

(cont’d)

Register No.

Name

Description

SVB