xxiii

ServoParameter2

-

ServoParameter2

GetNumber

IWxx37

Second requested parameter number (Pn)

GetValue

ILxx3A

Second requested parameter value

SetNumber

OWxx54

The number of the second amplifier parameter to be
read or set

SetSize

OWxx55

The size of the second amplifier parameter data

SetValue

OLxx56

The value to be set for the second amplifier parameter

SettingsMask

OWxx00

Various Servo bits packed into a word (mask)

SignalSelectionWord

OWxx04

Selects latch input signal and offset input signal.

Simulate

OBxx001

In simulation mode, servo will not move.

SimulationActive

IBxx0C6

Simulation active or machine locked (MLKL)

SimulationActiveN

IBxx2C5

Servo status MLOCK

Speed

-

Speed

Actual

ILxx40

Actual motor speed

Commanded

OLxx10

Commanded speed in units based on UnitType

CommandedResponse

ILxx20

Speed commanded response

Override

OWxx18

The percentage of commanded speed actually
achieved 100=1%

TorqueLimit

OLxx14

Maximum torque allowed during speed control

StatusMask

IWxx0C

Status mask

StatusMaskN

IWxx2C

Servo status mask

Torque

-

Torque

ActivateFwdLimit

OBxx008

Enables external forward torque limit set by servo
parameter.

ActivateRevLimit

OBxx009

Enables external reverse torque limit set by servo
parameter.

Actual

ILxx42

Actual motor torque

Commanded

OLxx0C

The commanded motor torque in % of rated 100=1%

Limited

IBxx2C9

Servo status T_LIM

SpeedLimit

OWxx0E

Maximum speed allowed during torque control

UnitsWord

OWxx03

BITS 0 to 3, Set speed units 0=Ref/s 1=10

n

ref/min

2=% BITS 4 to 7, Set acc/dec units 0=Ref/s

2

1=ms

BITS 8 to 11, Set acc/dec filter 0=none 1=exponential
2=moving average

Warning

-

Warning

Active

IBxx2C1

Servo status WARNING

AllMask

ILxx02

Warning mask

Communication

IBxx029

Servo communication warning

DynamicParameterOutOfRange

IBxx021

Dynamic parameter out of range warning

FollowingError

IBxx020

Following error warning

InvalidCommand

IBxx024

Command Setting Error

Mlink

IBxx023

Servo warning

NegativeOvertravel

IBxx027

Negative overtravel warning

PositiveOvertravel

IBxx026

Positive overtravel warning

ServoNotEnabled

IBxx028

Servo not energized warning

StaticParameterOutOfRange

IBxx022

Static parameter out of range warning

(cont’d)