2 motion setting parameter details, 2 motion setting parameter det, 2 motion setting parameter details -68 – Yaskawa MP2200 Machine Controller User Manual

Page 188: 1 ) run commands

Advertising
background image

4 Motion Parameters

4.4.2 Motion Setting Parameter Details

4-68

4.4.2 Motion Setting Parameter Details

The motion setting parameters are listed in the following tables.

Note)

: The labels shown in reverse type indicate that the parameter is

enabled during the corresponding control mode (position control here).

( 1 ) Run Commands

Position

OW††00

Run Commands

Setting Range

Setting Unit

Default Value

Bit Setting

0000 Hex

OW††00

Bit 0

Servo ON

Sends a SERVO ON command to the SERVOPACK.
0: Servo OFF (default)
1: Servo ON

Bit 1

Machine Lock

In machine lock mode, the Target Position (CPOS) (monitoring parameter IL††10) will be updated
but no movement will actually occur in the axis.
A change in the machine lock mode status is put into effect after all pulses have been distributed. The
machine lock mode cannot be changed during speed or torque control.
0: Machine lock mode released (default)
1: Machine lock mode

Bit 4

Latch Request

Store the current position when the latch signal turns ON as the Machine Coordinate Latch Position
(LPOS) (monitoring parameter IL††18).
When latch detection is completed, the Latch Completed bit will turn ON in the Position Management
Status (monitoring parameter IW††0C, bit 2).
To perform latch detection again, change this bit from 0 to 1.
Set the latch signal to be used in Latch Input Signal Type of Function 2 (setting parameter OW††04,
bits 0 to 2).
Do not set this bit to 1 during execution of the motion commands for zero point return, external
positioning, or latch.
0: Latch request OFF (default)
1: Latch request ON

Bit 5

Absolute Data Read Request

An Absolute Data Read can be started by setting this bit to 1 (effective on leading edge of signal) from
the ladder program.
Up to two reads will be performed, including the one retry.
0: OFF (default)
1: ON

Bit 6

POSMAX Preset

Preset the POSMAX Number of Turns (monitoring parameter IL††1E) to the value set for the Preset
Data of POSMAX Turn (setting parameter OL††4C).
0: POSMAX Preset OFF (default)
1: POSMAX Preset ON