4.3 SVB-01 Module Parameter Details

4-43

( 30 ) SERVOPACK Commands

OW††4F

Servo Alarm Monitor Number

Setting Range

Setting Unit

Default Value

0 to 10

0

Set the number of the alarm to monitor.
Set the number of the alarm to monitor for the ALM_MON or ALM_HIST motion command.
The result of monitoring will be stored as the Servo Alarm Code (monitoring parameter IW††2D).
Refer to Chapter 5 Motion Commands for details.

OW††50

Servo Constant Number

Setting Range

Setting Unit

Default Value

0 to 65535

0

Set the number of the SERVOPACK parameter.
Set the number of the SERVOPACK parameter to be processed for the PRM_RD or PRM_WR motion command.
Refer to Chapter 5 Motion Commands for details.

OW††51

Servo Constant Number Size

Setting Range

Setting Unit

Default Value

1, 2

1

Set the number of words in the SERVOPACK parameter.
Set the number of words in the SERVOPACK parameter to be processed for the PRM_RD or PRM_WR motion command.
Refer to Chapter 5 Motion Commands for details.

OL††52

Servo User Constant

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

0

Set the setting for the SERVOPACK parameter.
Set the setting value to be written to the SERVOPACK parameter with the PRM_WR motion command.
Refer to Chapter 5 Motion Commands for details.

OW††54

Auxiliary Servo User
Constant Number

Setting Range

Setting Unit

Default Value

0 to 65535

0

Set the number of the SERVOPACK parameter.
Set the number of the SERVOPACK parameter to be processed for the PRM_RD or PRM_WR motion subcommand.
Refer to Chapter 5 Motion Commands for details.

OW††55

Auxiliary Servo Constant
Number Size

Setting Range

Setting Unit

Default Value

1, 2

1

Set the number of words in the SERVOPACK parameter.
Set the number of words in the SERVOPACK parameter to be processed for the PRM_RD or PRM_WR motion subcommand.
Refer to Chapter 5 Motion Commands for details.

OL††56

Auxiliary Servo User
Constant

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

0

Set the setting for the SERVOPACK parameter.
Set the setting value to be written to the SERVOPACK parameter with the PRM_WR motion subcommand.
Refer to Chapter 5 Motion Commands for details.

Position

Phase

Speed

Torque

Position

Phase

Speed

Torque

Position

Phase

Speed

Torque

Position

Phase

Speed

Torque

Position

Phase

Speed

Torque

Position

Phase

Speed

Torque

Position

Phase

Speed

Torque

Advertising
This manual is related to the following products: