3 ) related parameters, 4 ) timing charts – Yaskawa MP2200 Machine Controller User Manual

Page 329

Advertising
background image

5.2 Motion Command Details

5-99

( 3 ) Related Parameters

[ a ] Setting Parameters

[ b ] Monitoring Parameters

( 4 ) Timing Charts

[ a ] Normal End

Parameter

Name

Setting

OB††000

Servo ON

Turn the power to the Servomotor ON and OFF.
1: Power ON to Servomotor; 0: Power OFF to Servomotor
Turn OFF the power before setting the Motion Command (OW††08) to 22.

OW††08

Motion Command

Starts resetting the absolute encoder when this parameter is set to 22. Even if this
parameter is set to 0 during command execution, it will be ignored and execution will
be continued.

OB††090

Command Pause

This parameter is ignored for the ABS_RST command.

OB††091

Command Abort

This parameter is ignored for the ABS_RST command.

Parameter

Name

Monitor Contents

IB††000

Motion Controller
Operation Ready

Indicates the communication status between the Machine Controller and
SERVOPACK.
ON: Communication synchronized, OFF: Communication disconnected

IB††001

Servo ON

Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor

IL††02

Warning

Stores the most current warning.

IL††04

Alarm

Stores the most current alarm.

IW††08

Servo Command
Type Response

Indicates the motion command that is being executed.
The response code will be 22 during ABS_RST command execution.

IB††090

Command Executing

Turns ON during ABS_RST command execution and turns OFF when execution has
been completed.

IB††091

Command Hold
Completed

Always OFF for the ABS_RST command.

IB††093

Command Error
Occurrence

Turns ON if an error, such as a communication error, occurs during ABS_RST
command execution. Command execution will be canceled.

IB††097

Absolute Encoder
Reset Completed

Turns ON when resetting the absolute encoder has been completed.

IB††098

Command Execution
Completed

Turns ON when ABS_RST command execution has been completed.

OW

08 = 22 (ABS_RST)

IW

08 = 22 (ABS_RST)

IW

090 (BUSY)

IW

093 (FAIL)

IW

097 (ABS_RSTC)

IW

098 (COMPLETE)

IW

000 (SVCRDY)

Undefined length
of time (approx. 2 s)

Undefined length of time

Advertising