5 Motion Commands

5.2.3 Zero Point Return (ZRET)

5-20

Note) Reverse type in

: Parameters only for the SVA-01 Module.

[ d ] C-Phase Method (OW††3C = 3)

Travel is started at the approach speed in the direction specified in the parameters. When the rising
edge of the phase-C pulse is detected, the speed is reduced to the creep speed and positioning is
performed. When positioning has been completed, a machine coordinate system is established with
the final position as the zero point.
The moving amount after the phase-C pulse is detected is set in the Home Offset. If an OT signal is
detected during the zero point return operation, an OT alarm will occur.

* 1. The SERVOPACK P-OT signal.
* 2. The SERVOPACK N-OT signal.

OB††058

Deceleration LS Signal
(DEC1) for Zero Point
Return

When bit 0 of fixed parameter No. 21 is 0, input the DEC1 signal
from the ladder program.

NOT

*2

POT

*1

Start

Zero Point

Creep Speed

(OL

40)

Home Offset

(OL

42)

Phase-C pulse

Approach Speed

(OL

3E)

Parameter

Name

Setting

OW††3C

Home Return Type

3: C-Phase Method

OB††093

Home Direction

Set the zero point return direction.

OL††3E

Approach Speed

Set the speed to use when starting a zero point return. Only a positive
value can be set; a negative value will result in an error.

OL††40

Creep Speed

Set the speed to use after detecting the phase-C pulse. Only a positive
value can be set; a negative value will result in an error.

OL††42

Home Offset

Set the travel distance from the point where a phase-C pulse is detected.
If the sign is positive, travel will be toward the zero point return direction;
if the sign is negative, travel will be away from the zero point return
direction.