Yaskawa MP2200 Machine Controller User Manual

Page 79

Advertising
background image

3.1 SVB-01 Module Setup

3-7

MECHATROLINK-II (17-byte Mode)

• Master

* If the communication cycle is 0.5 ms, the maximum number of retry stations is 5.

• Slaves

Item

Details

Default Value

Transmission
speed

Fixed value; display only.

10 Mbps

Transmission byte

Fixed value; display only.

16 bytes

Communication
cycle

0.5 ms or 1 ms

1 ms

SigmaWin

Set whether or not there is a SigmaWin connection.
Selections: Use/Not use

Not use

No. of retry to
slaves

Sets the number of retry stations.
Setting range: 0 to 7

1

Number of slaves

Automatically determined by the SigmaWin setting and the number of retry
stations setting. The results is displayed and cannot be changed.
Setting range: 0 to 15
The number of slave stations is calculated using the following equation.

 

SigmaWin Yes: 1, No: 0

• Communication cycle: 0.5 ms

Number of slave stations = 6

− (No. of retry stations

+ SigmaWin)

• Communication cycle: 1 ms

Number of slave stations = 15

− (No. of retry stations + SigmaWin)

14

Item

Details

Default Value

Transmission
speed

Fixed value; display only.

10 Mbps

Transmission byte

Fixed value; display only.

16 bytes

Communication
cycle

Setting not required.

1 ms

SigmaWin

Setting not required.

Not use

No. of retry to
slaves

Setting not required.

1

Number of slaves

Fixed value; display only.

30

Advertising
This manual is related to the following products: