10 Troubleshooting

10.1.4 Causes of the “Command Error End” Status (SVB-01 Only)

10-24

12

Change Filter Time
Constant (SCC)

Alarm occurred.

Communication is not synchronized.

“Servo Driver Synchronization Communication Error”
alarm

Command when pulse distribution has not been
completed (DEN = OFF).

“Filter Time Constant Change Error” alarm

A Servo parameter write operation was not completed
within the required time.

“Servo Driver Command Timeout Error” alarm

An A.94 or A.95 warning occurred in the Servo.

“Servo Driver Error” warning

13

Change Filter Type
(CHG_FILTER)

Alarm occurred.

Communication is not synchronized.

“Servo Driver Synchronization Communication Error”
alarm

Command when pulse distribution has not been
completed (DEN = OFF).

“Filter Type Change Error” alarm

The filter type setting is not within the allowed setting
range.

“Setting Parameter Error” warning

14
15
16

Change Speed Loop
Gain (KVS)
Change Position
Loop Gain (KPS)
Change Speed Feed
Forward (KFS)

Alarm occurred.

Communication is not synchronized.

“Servo Driver Synchronization Communication Error”
alarm

A Servo parameter write operation was not completed
within the required time.

“Servo Driver Command Timeout Error” alarm

An A.94 or A.95 warning occurred in the Servo.

“Servo Driver Error” warning

17
18

Read SERVOPACK
Parameter
(PRM_RD)
Write SERVOPACK
Parameter
(PRM_WR)

Alarm occurred.

Communications are not synchronized.

“Servo Driver Synchronization Communication Error”
alarm

A Servo parameter read operation was not completed
within the required time.

“Servo Driver Command Timeout Error” alarm

An A.94 or A.95 warning occurred in the Servo.

“Servo Driver Error” warning

The parameter number or size setting is not within the
allowed setting range.

“Setting Parameter Error” warning

19
20

Monitor
SERVOPACK Alarms
(ALM_MON)
Monitor
SERVOPACK Alarm
History (ALM_HIST)

A command to the SERVOPACK was not completed
within the required time.

“Servo Driver Command Timeout Error” alarm

The Servo Alarm Monitor Number setting is not
within the allowed setting range.

“Setting Parameter Error” warning

21

Clear SERVOPACK
Alarm History
(ALMHIST_CLR)

A command to the SERVOPACK was not completed
within the required time.

“Servo Driver Command Timeout Error” alarm

22

Reset Absolute
Encoder (ABS_RST)

Command sent to

Σ Series SERVOPACK.

No alarm or warning

Command sent while Servo ON.

No alarm or warning

Communication is not synchronized.

“Servo Driver Synchronization Communication Error”
alarm

A command to the SERVOPACK was not completed
within the required time.

“Servo Driver Command Timeout Error” alarm

23

Speed Reference
(VELO)

Command was sent while connected through
MECHATROLINK-I.

No alarm or warning

Alarm occurred.

Communication is not synchronized.

“Servo Driver Synchronization Communication Error”
alarm

(cont’d)

Motion Command Code

Cause of Command Error End Status

Simultaneously Occurring Warnings or Alarms