1.2 SVB-01 Module Overview and Features

1-5

1.2.3 System Configuration Example

The following diagram shows a system configuration example.

1.2.4 System Configuration Precautions

The following precautions must be followed when designing a system using the SVB-01 Module.

• Use the connecting cables and connectors recommended by Yaskawa.

Yaskawa has a range of cables. Always check the device to be used and select the correct cable for
the device.

• Different SERVOPACKs are connected to MECHATROLINK-I and MECHATROLINK-II.

Refer to the list and select the appropriate SERVOPACKs.

• If devices compatible with MECHATROLINK-I (4 Mbps) and with MECHATROLINK-II (10

Mbps) are used together, make the settings for MECHATROLINK-I (4 Mbps).

• When connecting SERVOPACKs via MECHATROLINK, connect the overtravel, zero point

return deceleration limit switch, and external latch signals to the SERVOPACKs.

MP2300

MECHATROLINK-II

SGDS

M

IO2310

PL2900

PL2910

NS1

15

SGDH

M

MECHATROLINK-II

SGDS

M

IO2310

PL2900

PL2910

NS1

15

SGDH

M

Ethernet

RS-232C

218IF LIO-01

SVB-01

MPE720

External I/O

24-VDC

power

supply

MECHATROLINK-
compatible I/O Modules

Servos

MECHATROLINK-
compatible I/O Modules

Servos

External I/O

Control panel