3 Motion Module Setup

3.1.2 Self-configuration

3-8

MECHATROLINK-II (32-byte Mode)

• Master

* If the communication cycle is 0.5 ms, the maximum number of retry stations is 3.

• Slaves

Item

Details

Default Value

Transmission
speed

Fixed value; display only.

10 Mbps

Transmission byte

Fixed value; display only.

31 bytes

Communication
cycle

0.5 ms, 1 ms, 1.5 ms, or 2 ms

1 ms

SigmaWin

Set whether or not there is a SigmaWin connection.
Selections: Use/Not use

Not use

No. of retry to
slaves

Sets the number of retry stations.
Setting range: 0 to 7

1

Number of slaves

Automatically determined by the SigmaWin setting and the number of retry
stations setting. The results is displayed and cannot be changed.
Setting range: 0 to 15
The number of slave stations is calculated using the following equation.

 

SigmaWin Yes: 1, No: 0

• Communication cycle: 0.5 ms

Number of slave stations = 4

− (No. of retry stations

+ SigmaWin)

• Communication cycle: 1 ms

Number of slave stations = 9

− (No. of retry stations + SigmaWin)

• Communication cycle: 1 ms

Number of slave stations = 15

− (No. of retry stations + SigmaWin)

• Communication cycle: 1 ms

Number of slave stations = 21

− (No. of retry stations + SigmaWin)

8

Item

Details

Default Value

Transmission
speed

Fixed value; display only.

10 Mbps

Transmission byte

Fixed value; display only.

31 bytes

Communication
cycle

Setting not required.

1 ms

SigmaWin

Setting not required.

Not use

No. of retry to
slaves

Setting not required.

1

Number of slaves

Fixed value; display only.

30