Monitor.Type

Selects which value will be returned from the servopack. Bits 4 to 7 set
monitor2and bits C to F set monitor4

OWxx4F

Alarm.MonitorNumber

This value determines which of the last 10 alarm codes are returned.

OWxx50

ServoParameter.SetNumber

The number of the amplifier parameter to be read or set

OWxx51

ServoParameter.SetSize

The size of the amplifier parameter data

OLxx52

ServoParameter.SetValue

The value to be set for the amplifier parameter

OWxx54

ServoParameter2.SetNumber

The number of the second amplifier parameter to be read or set

OWxx55

ServoParameter2.SetSize

The size of the second amplifier parameter data

OLxx56

ServoParameter2.SetValue

The value to be set for the second amplifier parameter

OWxx5C

Command.StaticParameterNumber

The number of the static parameter to be read when Command2=5

OLxx5E

Encoder.Set.AbsolutePositionLS

Used to set the absolute position used in infinite
length applications.

OLxx60

Encoder.Set.AbsolutePositionMS

Used to set the absolute position used in infinite
length applications.

OLxx62

Encoder.Set.ModularPositionLS

Used to set the modularized position used in infinite
length applications.

OLxx64

Encoder.Set.ModularPositionMS

Used to set the modularized position used in infinite
length applications.

OBxx95

Position.MoveType

Selects positioning. 0=incremental 1=absolete