5.3 Motion Subcommands

5-123

( 2 ) Related Parameters

[ a ] Setting Parameters

[ b ] Monitoring Parameters

( 3 ) Timing Charts

[ a ] Normal End

Parameter

Name

Setting Contents

OW††0A

Motion Subcommand

The Monitor Status command is executed when this parameter is set to 3.

OW††4E

Servo User Monitor

Set the information (managed by the Servo Driver) that you want to monitor.

Parameter

Name

Monitoring Contents

IW††0A

Motion Subcommand
Response Code

Indicates the motion subcommand that is being executed.
The response code is 3 during SMON command execution.

IB††0B0

Command Executing

Turns ON during SMON command execution and turns OFF when execution has
been completed.

IB††0B3

Command Error End

Turns ON if an error occurs during SMON command execution. Turns OFF when
another command is executed.

IB††0B8

Command Execution
Completed

Turns ON when SMON command execution has been completed.

IW††2F

Servo Driver User
Monitor Information

Stores either the monitor selection or the data actually being monitored in the user
monitor.

IL††34

Servo User Monitor 4

Stores the result of the selected monitor operation.

OW

0A=3 (SMON)

IW

0A=3 (SMON)

IB

0B0 (BUSY)

IW

2D, bits12 to 15

Undefined

Monitor 4 = Set value

IB

0B8 (COMPLETE)

IB

0B3 (FAIL)

IL

34

Undefined

Monitoring result