2 motion setting parameter details, 2 motion setting parameter det, 2 motion setting parameter details -23 – Yaskawa MP2200 Machine Controller User Manual

Page 143: 1 ) run commands

Advertising
background image

4.3 SVB-01 Module Parameter Details

4-23

4.3.2 Motion Setting Parameter Details

The motion setting parameters are listed in the following tables.

Note)

: The labels shown in reverse type indicate that the parameter is enabled

during the corresponding control mode (position control shown here).

( 1 ) RUN Commands

Position

OW††00

RUN Commands

Setting Range

Setting Unit

Default Value

0000H

OW††00

Bit 0

Servo ON

Set whether or not to turn ON (excite) the SERVOPACK.
0: Servo OFF (default)
1: Servo ON

Bit 1

Machine Lock

During the machine lock mode, the Target Position (CPOS) (monitoring parameter IL††10) will be
updated but no movement will occur on the axis. Changes to the machine lock mode are valid after all
pulses have been distributed. The machine lock mode cannot be changed during speed or torque
control.
0: Machine lock mode released (default)
1: Machine lock mode

Bit 4

Latch Request

Store the current position when the latch signal turns ON in the Machine Coordinate Latch Position
(LPOS) (monitoring parameter IL††18).
When latch detection is completed, the Latch Completed bit will turn ON in the Position Management
Status (monitoring parameter IW††0C, bit 2).
To perform latch detection again, change this bit from 0 to 1.
Set the latch signal to be used in Latch Input Signal Type of Function 2 (setting parameter OW††04,
bits 0 to 3).
This function is achieved using the Servo command expansion area and can be executed only with the
MECHATROLINK-II, 32-byte Mode communication method.
Do not change this bit to 1 during execution of the motion commands for zero point return, external
positioning, or latching. Doing so may result in a warning at the SERVOPACK.

* T

t

1

+ t

2

+ t

3

Where
T: Latch processing time
t

1

: Communication cycle

t

2

: Two scans

t

3

: SERVOPACK latch processing preparations time (

≤ 4 ms)

0: Latch request OFF (default)
1: Latch request ON

Position

Phase

Speed

Torque

OB

004

IB

0C2

T

Latch signal

Advertising