2 motion parameter settings, Nder 8.2.2 motion parameter settings for, 2 motion parameter settings -8 – Yaskawa MP2200 Machine Controller User Manual

Page 424: 1 ) motion fixed parameters

Advertising
background image

8 SVR Virtual Motion Module

8.2.2 Motion Parameter Settings

8-8

8.2.2 Motion Parameter Settings

This section describes the motion parameters used by the SVR.

( 1 ) Motion Fixed Parameters

[ a ] Run Mode

[ b ] Function Selection 1

[ c ] Reference Unit Setting

[ d ] Number of Decimal Places

[ e ] Command Unit per Revolution

No. 0

Run Mode

Setting Range

Setting Unit

Default Value

0, 1

1

Specify the application method of the axis.
0: Normal Running, 1: Axis unused (default)

No. 1

Function Selection 1

Setting Range

Setting Unit

Default Value

0000H

No. 1

Bit 0

Axis Type

0: Linear (Finite length axis) (default), 1: Rotating (Infinite length axis)

No. 4

Command Unit

Setting Range

Setting Unit

Default Value

0 to 3

0

Set the unit for the reference that is input.

0: pulse (electronic gear disabled)

1: mm

2: deg

3: inch

No. 5

Number of Decimal Places

Setting Range

Setting Unit

Default Value

0 to 5

3

Set the number of digits to the right of the decimal point in input references.
Example: If Command Unit = mm and Number of Decimal Places = 3
Then, a reference unit of 1 = 0.001 mm

No. 6

Command Unit per Revolution

Setting Range

Setting Unit

Default Value

1 to 2

31

−1

Reference unit

10000

Specify the amount of travel in the load as the number of reference units for each turn of the load shaft.