Important – Yaskawa MP2200 Machine Controller User Manual

Page 251

Advertising
background image

5.2 Motion Command Details

5-21

[ e ] DEC2 + ZERO Signal Method (OW††3C = 4)

With this method, the machine's position is confirmed by the ON/OFF status of the DEC2 signal and
the retracting operation is performed automatically, so the zero point return is always performed with
the same conditions.

This zero point return method can be used with the SVA-01 Module only.

Starting the Zero Point Return in the High Region

1.

Travel is started in the forward direction at the speed specified by the Speed
Reference (setting parameter OL††10).

2.

When the falling edge of the DEC2 signal is detected, the axis decelerates to a stop.

3.

After decelerating to a stop, the axis travels in the reverse direction at the Approach
Speed (setting parameter OL††3E).

4.

When the rising edge of the DEC2 signal is detected, the axis decelerates to a stop.

5.

After decelerating to a stop, the axis travels in the forward direction at the Creep
Speed (setting parameter OL††40).

6.

After the falling edge of the DEC2 signal is detected, the position is latched when the
rising edge of the ZERO signal is detected.

7.

The axis moves from the latched position by the distance set in the Home Offset
(setting parameter OL††42) and stops. The machine coordinate system is
established with this final position as the zero point.

If an OT signal is detected during the zero point return operation, an OT alarm will occur.

INFO

Start

Home Offset

DEC2

(DI_5 or OW

05, bit 8)

N-OT

(DI_4)

P-OT

(DI_3)

Approach Speed (OL

3E)

High region

Low region

End

Speed Reference
(OL

10)

ZERO signal
latch at this point

Creep Speed
(OL

40)

ZERO signal
(DI_2)

IMPORTANT

Advertising
This manual is related to the following products: