4 ) timing charts – Yaskawa MP2200 Machine Controller User Manual

Page 325

Advertising
background image

5.2 Motion Command Details

5-95

[ b ] Monitoring Parameters

( 4 ) Timing Charts

[ a ] Normal End

[ b ] Error End

Parameter

Name

Monitor Contents

IL††02

Warning

Stores the most current warning.

IL††04

Alarm

Stores the most current alarm.

IW††08

Servo Command
Type Response

Indicates the motion command that is being executed.
The response code will be 20 during ALM_HIST command execution.

IB††090

Command Executing

Turns ON during ALM_HIST command execution and turns OFF when execution has
been completed.

IB††091

Command Hold
Completed

Always OFF for ALM_HIST command.

IB††093

Command Error End

Turns ON if an error occurs during ALM_HIST command execution. Turns OFF when
another command is executed.

IB††098

Command Execution
Completed

Turns ON when ALM_HIST command execution has been completed.

IW††2D

Servo Alarm Code

Stores the SERVOPACK alarm code that was read.

OW

08 = 20 (ALM_HIST)

IW

08 = 20 (ALM_HIST)

IB

090 (BUSY)

IW

2D

Alarm code (0)

Alarm
code (0)

Specified
alarm code

IB

098 (COMPLETE)

IB

093 (FAIL)

Undefined length
of time

Alarm code (0)

Alarm
code (0)

Alarm
code (0)

OW

08 = 20 (ALM_HIST)

IW

08 = 20 (ALM_HIST)

IB

090 (BUSY)

IW

2D

IB

098 (COMPLETE)

IB

093 (FAIL)

Undefined length
of time

Advertising
This manual is related to the following products: