4.4 SVA-01 Module Parameter Details

4-95

IL††16

Machine Coordinate Feedback Position (APOS)

Range

Unit

−2

31

to 2

31

−1

Reference unit

Stores the feedback position in the machine coordinate system managed by the Motion Module.

• This parameter will be set to 0 when a Zero Point Return (ZRET) is executed.

Note) When an infinite length axis type is selected, the position ranges from 0 to (Infinite Length Axis

Reset Position

− 1).

IL††18

Machine Coordinate Latch Position (LPOS)

Range

Unit

−2

31

to 2

31

−1

Reference unit

Stores the latch position when the latch has been completed.

IL††1A

Position Error (PERR)

Range

Unit

−2

31

to 2

31

−1

Reference unit

Stores the following error (Machine Coordinate System Position (IL††12)

− Machine Coordinate Feedback Position

(IL††16)) managed by the Motion Module.

IL††1C

Reference Position Increment Monitor

Range

Unit

−2

31

to 2

31

−1

Reference unit

Stores the pulse distribution amount calculated every 500

µs cycle.

IW††1E

POSMAX Number of Turns

Range

Unit

−2

31

to 2

31

−1

Rev

This parameter is valid for an infinite length axis.
The count stored in this parameter goes up and down every time the current position exceeds the Maximum Value of Rotary
Counter (POSMAX) (fixed parameter 10).