Yaskawa MP2200 Machine Controller User Manual

Page 292

Advertising
background image

5 Motion Commands

5.2.5 Latch (LATCH)

5-62

[ b ] Monitoring Parameters

Parameter

Name

Monitor Contents

IB††001

Servo ON

Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor

IL††02

Warning

Stores the most current warning.

IL††04

Alarm

Stores the most current alarm.

IW††08

Servo Command
Type Response

Indicates any alarms that have occurred during execution.
The response code is 6 during LATCH operation.

IB††090

Command Executing

Always OFF for LATCH operation.

IB††091

Command Hold
Completed

Always OFF for LATCH operation.

IB††093

Command Error End

Turns ON if an error occurs during LATCH operation. The axis will decelerate to a stop
if it is moving. Turns OFF when another command is executed.

IB††098

Command Execution
Completed

Always OFF for LATCH operation.

IB††0C0

Distribution
Completed

Turns ON when distribution has been completed for the move command.
Turns OFF during execution of a move command.

IB††0C1

Positioning
Completed

Turns ON when distribution has been completed and the current position is within the
Positioning Completed Width. OFF in all other cases.

IB††0C2

Latch Completed

This bit turns OFF when a new latch command is executed and turns ON when the latch
has been completed. The latched position is stored as the Machine Coordinate Latch
Position (monitoring parameter IL††18).

IB††0C3

Position Proximity

The operation depends on the setting of the Positioning Completed Width 2 (setting
parameter OL††20).

OL††20 = 0: Turns ON when pulse distribution has been completed (DEN = ON).
OL††20

≠0: Turns ON when MPOS - APOS < Position Proximity Setting even if

pulse distribution has not been completed.

OFF in all other cases.

IL††18

Machine Coordinate
Latch Position

Stores the current position in the machine coordinate system when the latch signal
turned ON.

Advertising
This manual is related to the following products: