9.1 Controlling Vertical Axes

9-5

[ c ] Pn507 and Pn508 (Brake ON Timing when Motor Running)

Adjust the timing of the holding brake when the motor is running with the following parameters so
that the brake is applied after the Servomotor stops.

When using a Servomotor with a brake, set the timing of applying the brake when the Servo turns
OFF during motor running due to an /S-ON input signal or alarm.

The brake on the Servomotor is designed as a holding brake and it must be applied only after the motor
has stopped. Adjust this parameter while observing machine operation.

Parameter

Name

Unit

Setting

Range

Default

Control Mode

Pn507

Speed Level for BK Signal
Output when Motor Running

min

−1

0 to 10000

100

Speed, torque, position
control

Pn508

Output Timing of BK Signal
when Motor Running

10 ms

0 to 100

50

Speed, torque, position
control

Pn507

Pn508

/S-ON input or
alarm occurred.
Power OFF

Motor speed

/BK output

Brake
released

Servo ON

Servo OFF

Stop with dynamic

brake or by coasting

(Pn001.0)

Brake holding

INFO