9 Utility Functions

9.3.3 Processing after an Alarm Occurs

9-18

ΠThe software limit function is enabled only after completing a Zero Point Return or Zero Point

Setting operation.

ΠIf any fixed parameters are changed and saved, the Zero Point Return or Zero Point Setting

operation must be performed again.

ΠDisable the software limits in the SERVOPACK.
Œ

Σ SERVOPACK: Cn-0014, bits 2 and 3

Œ

Σ-ΙΙ or Σ-ΙΙΙ S-ERVOPACK: Pn801.0 = 3 (default value)

9.3.3 Processing after an Alarm Occurs

( 1 ) Alarm Information

If a software limit is exceeded, a Positive/Negative Soft Limit (Positive/Negative Software Limit)
alarm will occur. This alarm can be monitored in the Alarm monitoring parameter (IL††04).

( 2 ) Clearing Software Limit Alarms

Clear software limit alarms using the procedure below.

1.

Resetting Alarms

Set the Alarm Clear bit to 1 in the RUN Commands (OW††00 bit F) to clear the alarm.

2.

Returning

Use the FEED or STEP command to return past the software limit.

IMPORTANT

Register Number

Name

Contents

IL††04

Alarm

Bit 3: Positive Software Limit
Bit 4: Negative Software Limit

Register Number

Name

Contents

OW††00

RUN Commands

Bit F: Clear Alarm

Commands will be received in the return direction.

Servo-
motor

An alarm will occur again if a command is
given in the direction of the software limit
that was activated.

Software Limit,

lower limit

Software Limit,

upper limit