3 ) detailed descriptions, Important – Yaskawa MP2200 Machine Controller User Manual

Page 389

Advertising
background image

7.2 Startup the Absolute Position Detection Function

7-5

* SERVOPACK Models

( 3 ) Detailed Descriptions

[ a ] Encoder Selection

• MP2200/MP2300 fixed parameter 30
• SERVOPACK parameter Cn-0001, bit E or Pn002.2

For an axis performing absolute position detection, set MP2300 fixed parameter 30 and
SERVOPACK parameter Cn-0001, bit E, or parameter Pn002.2 as shown in the following

table.

Both the MP2200/MP2300 and SERVOPACK parameters are valid, so be sure to set both of
them.

If the above settings are not used, correct motion control will not be performed. Set the parameters
carefully.

Σ-III Series

*

Pn000.0

Direction Selection

0: Sets counterclockwise (CCW) rotation as forward

direction.

1: Sets clockwise (CW) rotation as forward direction

(reverse rotation mode).

Pn205

Multiturn Limit Setting

0 to 65535

Rev

Pn002.2

Absolute Encoder Usage

0: Uses absolute encoder as an absolute encoder.
1: Uses absolute encoder as an incremental encoder.

SERVOPACKs Applicable to the

SVB-01

SERVOPACKs Applicable to

the SVA-01

Σ Series

SGD-†††N,
SGDB-††AN

SGDA-†††S,
SGDB-††AD†-†, -††DD

Σ-II Series

SGDH-†††E + NS100/NS115

SGDM-†††DA, -††AD†,
SGDH-††DE, -††AE, -†††E

Σ-III Series

SGDS-†††1††

SGDS-†††-01†, -†††-02†, -†††05, -
††A†††, -††F†††

Parameter

Setting

MP2200/MP2300 fixed parameter 30

Absolute encoder

Σ Series Cn-0001, bit E

1: Absolute encoder

Σ-II, Σ-III Series Pn002.2

0: Uses absolute encoder as an absolute encoder.

IMPORTANT