2 Module Specifications and Connections

2.1.1 General Specifications

2-4

* Only with MECHATROLINK-II

Servo Cont

ro

l

Communication Method

Single-send (communication cycle = transmission cycle) synchronous communication
Transmission/communication error detection (hardware) provided.
Synchronous communication error detection (software) provided.
Automatic recovery function not provided (recovery when alarm cleared).

I/O Registers

Input/output using motion registers (synchronized on high-speed scan)

Command Mode

Motion Command Mode/MECHATROLINK Transparent Command Mode

Supported Servomotors

Standard motors/linear motors/DD motors

Control Type

Position control, speed control, torque control, and phase control

Motion Commands

Positioning, External Positioning, Zero Point Return, Interpolation, Interpolation with
Position Detection, JOG operation, STEP operation, Speed Reference

*

, Torque Reference

*

,

Phase Control, etc.

Acceleration/Deceleration
Method

One-step asymmetric trapezoidal acceleration/deceleration, exponential acceleration/
deceleration filter, moving average filter

Position Unit

pulse, mm, inch, degree

Speed Unit

Reference units/s, 10

n

reference units/min, percentage of rated speed

Acceleration Unit

Reference units/s

2

, ms (acceleration from 0 until rated speed reached)

Torque Unit

Percentage of rated torque

Electronic Gear

Provided.

Position Control Method

Finite length position control, infinite length position control, absolute system infinite length
position control, and simple absolute system infinite length position control

Software Limit

Positive/negative direction for each point

Zero Point Return Method

13 types

SERVOPACK Parameter
Management

Parameters can be managed in the MPE720’s SERVOPACK Parameter Window.

In

vert

er

Control

Communication Method

Single-send (communication cycle = transmission cycle) asynchronous communication
Transmission/communication error detection (hardware) provided.
Synchronous communication error detection (software) not provided.
Automatic recovery function not provided (recovery by clearing alarm).

I/O Registers

Input/output using motion registers (synchronized on high-speed scan)

Command Mode

Motion Command Mode/MECHATROLINK Transparent Command Mode

Control Type

Speed control only (V/F, vector control and other control methods use inverter settings.)

Motion Commands

Inverter I/O control, etc.

Speed Unit

The speed unit depends on the inverter settings.

I/

O C

on

tr

ol

Communication Method

Single-send (communication cycle = transmission cycle) asynchronous communication
Transmission/communication error detection (hardware) provided.
Synchronous communication error detection not provided.
Automatic recovery function not provided.

I/O Registers

Input/output using I/O registers and synchronized on the high-speed scan or low-speed scan
(selectable).

Self-configuration Function

Module and slave devices can be automatically allocated.

Synchronization between Modules

Synchronization supported (enabled when power is cycled) when high-speed scan cycle =
communication cycle times n

(cont’d)

Item

Details

Advertising