5 ) timing charts – Yaskawa MP2200 Machine Controller User Manual

Page 332

Advertising
background image

5 Motion Commands

5.2.22 Speed Reference (VELO)

5-102

[ b ] Monitoring Parameters

( 5 ) Timing Charts

[ a ] Normal Execution

Parameter

Name

Monitor Contents

IB††001

Servo ON

Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor

IL††02

Warning

Stores the most current warning.

IL††04

Alarm

Stores the most current alarm.

IW††08

Servo Command
Type Response

Indicates the motion command that is being executed.
The response code will be 23 during VELO command execution.

IB††090

Command Executing

Turns ON when abort processing is being performed for VELO command. Turns OFF
when abort processing has been completed.

IB††091

Command Hold
Completed

Always OFF for VELO command.

IB††093

Command Error End

Turns ON if an error occurs during VELO command execution. The axis will
decelerate to a stop if it is operating. Turns OFF when another command is executed.

IB††098

Command Execution
Completed

Always OFF for VELO command.

IB††0C0

Distribution
Completed

Turns ON when pulse distribution has been completed for the move command.
Turns OFF during execution of a move command.

IB††0C1

Positioning
Completed

Turns ON when pulse distribution has been completed and the current position is
within the positioning completed range. OFF in all other cases.

IB††0C3

Position Proximity

The operation of this bit depends on the setting of Positioning Completed Width 2
(setting parameter OL††20).

• OL††20 = 0: Turns ON when pulse distribution has been completed (DEN = ON).
• OL††20

≠ 0: Turns ON when the absolute value of the difference between the

Machine Coordinate Feedback Position (monitoring parameter IL††16) and the
Machine Coordinate System Position (monitoring parameter IL††12) is less than
the Position Completed Width 2, even if pulse distribution has not been completed.

OFF in all other cases.

OW

08 = 23 (VELO)

IW

08 = 23 (VELO)

IB

090 (BUSY)

IB

098 (COMPLETE)

IB

093 (FAIL)

IB

0C0(DEN)

1 scan

Advertising