3 ) switch settings – Yaskawa MP2200 Machine Controller User Manual

Page 53

Advertising
background image

2.1 SVB-01 Module Specifications and Connections

2-7

( 3 ) Switch Settings

Both the DIP switch and rotary switches set the operating conditions for the SVB-01 Module. Use
the default settings when using the Module in Master Mode.

[ a ] DIP Switch

SIZE and SPD are valid only in Slave Mode. They will be ignored in Master Mode.

Setting Example

OFF

ON

SPD

SIZE

M/S

Name

Status

Operating Mode

Default Setting

Details

ON

Reserved.

OFF

Keep turned OFF.

OFF

Reserved.

M/S

ON

Slave Mode

OFF

Select Master or Slave Mode.

OFF

Master Mode

SIZE

ON

17 bytes

OFF

Select the number of send bytes.

OFF

32 bytes

SPD

ON

4 Mbps

OFF

Select the baud rate.

OFF

10 Mbps

Communication

Interface

Link

Communication

Switch Settings

MECHATROLINK-I

17-byte

MECHATROLINK-II

17-byte

32-byte

EXAMPLE

OFF
OFF
ON
ON

OFF
OFF
OFF
OFF

OFF
OFF
ON
OFF