25 ) filters – Yaskawa MP2200 Machine Controller User Manual

Page 201

Advertising
background image

4.4 SVA-01 Module Parameter Details

4-81

( 25 ) Filters

OW††3A

S-curve Acceleration Time

Setting Range

Setting Unit

Default Value

0 to 65535

0.1 ms

0

Sets the acceleration/deceleration filter time constant.
Always verify that pulse distribution has been completed (monitoring parameter IB††0C0 is ON) before changing the time
constant.
After setting the filter type to be used, change the time constant.
Once the filter type is set, the setting is held until the power is turned OFF or the filter type is changed.
There are two types of acceleration/deceleration filter: an exponential acceleration/deceleration filter and a moving average
filter.
The following table shows the relationship with related parameters.

OW††3B

Bias Speed for Exponential
Acceleration/Deceleration
Filter

Setting Range

Setting Unit

Default Value

0 to 32767

Speed Units (setting parameter

OW††03, bits 0 to 3)

0

Set the bias speed for exponential acceleration/deceleration with bias.

Position

Phase

Speed

Torque

OW

3A

OW

3A

Step input

No filter

Acceleration/deceleration used

OW

36

OW

3A

OW

3A

OW

38

OW

36

OW

38

OW

03, bits 8 to B = 0

Exponential Acceleration/
Deceleration Filter

OW

03, bits 8 to B = 1

Moving Average Filter

OW

03, bits 8 to B = 2

Position

Phase

Speed

Torque