Three-phase 400 v class, 6 main circuit wiring – Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 136

Advertising
background image

Drive Model

Terminal

Recomm. Gauge

AWG, kcmil

Wire Range

AWG, kcmil

Screw

Size

Tightening Torque

N·m (lb.in.)

2A0250

R/L1, S/L2, T/L3

3/0 × 2P

3/0 to 300

M12

32 to 40

(283 to 354)

U/T1, V/T2, W/T3

3/0 × 2P

3/0 to 300

⊖, ⊕1

3/0 to 300

⊕3

2 to 300

M10

18 to 23

(159 to 204)

3

3 to 300

M12

32 to 40

(283 to 354)

2A0312

R/L1, S/L2, T/L3

4/0 × 2P

3/0 to 300

M12

32 to 40

(283 to 354)

U/T1, V/T2, W/T3

3/0 × 2P

3/0 to 300

⊖, ⊕1

3/0 to 300

⊕3

3/0 to 300

M10

18 to 23

(159 to 204)

2

2 to 300

M12

32 to 40

(283 to 354)

2A0360

R/L1, S/L2, T/L3

250 × 2P

4/0 to 600

M12

32 to 40

(283 to 354)

U/T1, V/T2, W/T3

4/0 × 2P

4/0 to 600

⊖, ⊕1

250 to 600

⊕3

3/0 to 600

M10

18 to 23

(159 to 204)

1

1 to 350

M12

32 to 40

(283 to 354)

2A0415

R/L1, S/L2, T/L3

350 × 2P

250 to 600

M12

32 to 40

(283 to 354)

U/T1, V/T2, W/T3

300 × 2P

300 to 600

⊖, ⊕1

300 to 600

⊕3

3/0 to 600

M10

18 to 23

(159 to 204)

1

1 to 350

M12

32 to 40

(283 to 354)

<1> Install a GFCI when using this wire gauge in accordance with IEC/EN 61800-5-1.
<2> Install a GFCI, or use 10 mm

2

(AWG 8) copper wire when using this wire gauge in accordance with IEC/EN 61800-5-1.

Note:

When connecting peripheral devices or options to terminals

⊖, ⊕1, ⊕3, B1, and B2, refer to the instruction manual for each device. For

more information, contact Yaskawa or your nearest sales representative.

n

Three-Phase 400 V Class

Table 3.4 Wire Gauge and Torque Specifications (Three-Phase 400 V Class)

Drive Model

Terminal

Recomm. Gauge

AWG, kcmil

Wire Range

AWG, kcmil

Screw

Size

Tightening Torque

N·m (lb.in.)

4A0002
4A0004

R/L1, S/L2, T/L3

14

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

12

<1>

14 to 12

4A0005
4A0007
4A0009

R/L1, S/L2, T/L3

14

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

10

<1>

14 to 10

4A0011

R/L1, S/L2, T/L3

12

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

10

<1>

14 to 10

3.6 Main Circuit Wiring

136

YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide

Advertising