F7-06

(03EA) Subnet Mask 2

Subnet Mask 2

Sets the second most significant octet of network static Subnet

Mask.

Default: 255

Range: 0 to 255

F7-07

(03EB) Subnet Mask 3

Subnet Mask 3

Sets the third most significant octet of network static Subnet

Mask.

Default: 255

Range: 0 to 255

F7-08

(03EC) Subnet Mask 4

Subnet Mask 4

Sets the fourth most significant octet of network static Subnet

Mask.

Default: 0

Range: 0 to 255

F7-09

(03ED) Gateway Address 1

Gateway IP Add 1

Sets the most significant octet of network Gateway address.

Default: 192

Range: 0 to 255

F7-10

(03EE) Gateway Address 2

Gateway IP Add 2

Sets the second most significant octet of network Gateway

address.

Default: 168

Range: 0 to 255

F7-11

(03EF) Gateway Address 3

Gateway IP Add 3

Sets the third most significant octet of network Gateway

address.

Default: 1

Range: 0 to 255

F7-12

(03E0) Gateway Address 4

Gateway IP Add 4

Sets the fourth most significant octet of network Gateway

address.

Default: 1

Range: 0 to 255

F7-13

(03F1) Address Mode at Startup

IP Add Mode Sel

0: User Defined

1: BOOTP

2: DHCP

Select the option address setting method
0: Static

<3>

1: BOOTP

2: DHCP

Default: 2

Range: 0 to 2

F7-14

(03F2) Duplex Mode Selection

Duplex Select

0: Half Duplex

1: Auto Negotiate

2: Full Duplex

Selects duplex mode setting.

0: Half duplex forced

1: Auto-negotiate duplex mode and communication speed

2: Full duplex forced

Default: 1

Range: 0 to 2

F7-15

(03F3)

Communication Speed

Selection

Baud Rate

10: 10 Mbps

100: 100 Mbps

Sets the communication speed

10: 10 Mbps

100: 100 Mbps

Default: 10

Range: 10, 100

F7-16

(03F4)

Communication Loss

Timeout

CommLoss Tout

Sets the timeout value for communication loss detection in

tenths of a second. A value of 0 disables the connection timeout.

Example: An entered value of 100 represents 10.0 seconds.

Default: 0

Min.: 0

Max.: 300

F7-17

(03F5)

EtherNet/IP Speed

Scaling Factor

EN Speed Scale

Sets the scaling factor for the speed monitor in EtherNet/IP

Class ID 2AH Object.

Default: 0

Min.: -15

Max.: 15

F7-18

(03F6)

EtherNet/IP Current

Scaling Factor

EN Current Scale

Sets the scaling factor for the output current monitor in

EtherNet/IP Class ID 2AH Object.

Default: 0

Min.: -15

Max.: 15

F7-19

(03F7)

EtherNet/IP Torque

Scaling Factor

EN Torque Scale

Sets the scaling factor for the torque monitor in EtherNet/IP

Class ID 2AH Object.

Default: 0

Min.: -15

Max.: 15

F7-20

(03F8)

EtherNet/IP Power

Scaling Factor

EN Power Scale

Sets the scaling factor for the power monitor in EtherNet/IP

Class ID 2AH Object.

Default: 0

Min.: -15

Max.: 15

F7-21

(03F9)

EtherNet/IP Voltage

Scaling Factor

EN Voltage Scale

Sets the scaling factor for the voltage monitor in EtherNet/IP

Class ID 2AH Object.

Default: 0

Min.: -15

Max.: 15

F7-22

(03FA)

EtherNet/IP Time

Scaling

EN Time Scale

Sets the scaling factor for the time monitor in EtherNet/IP Class

ID 2AH Object.

Default: 0

Min.: -15

Max.: 15

F7-23 to

F7-32

(03FB to

0374)

Dynamic Output

Assembly Parameters

Parameters used in Output Assembly 116. Each parameter

contains a MEMOBUS/Modbus address. The value received for

Output Assembly 116 will be written to this corresponding

MEMOBUS/Modbus address. A MEMOBUS/Modbus address

value of 0 means that the value received for Output Assembly

116 will not be written to any MEMOBUS/Modbus register.

Default: 0

F7-33 to

F7-42

(0375 to

037E)

Dynamic Input

Assembly Parameters

Parameters used in Input Assembly 166. Each parameter

contains a MEMOBUS/Modbus address. The value sent for

Input Assembly 166 will be read from this corresponding

MEMOBUS/Modbus address. A MEMOBUS/Modbus address

value of 0 means that the value sent for Input Assembly 166 is

not defined by the user, therefore the option default register

value will be returned.

Default: 0

<1> Parameter setting value is not reset to the default value when the drive is initialized.
<2> Cycle power for setting changes to take effect.
<3> If F7-13 is set to 0, all IP addresses (F7-01 to F7-04) must be unique.