HOA Keypad Display

Minor Fault Name

LOP

Loss of Prime
The pump has lost its prime and P1-22 is set to 1.

Cause

Possible Solution

The measured quantity of water has

dropped below the level set in P1-19, Prime

Loss Level, for the time set in P1-20, Loss

of Prime Time, and the output frequency

has risen above P1-21, Prime Loss

Frequency. This could be due to a dry well,

air in the system, or no water in the system.

This is effective only when P1-22 Loss of

Prime Selection is set to 1 (alarm).

• If there is resistance in the pump, allow the system to pump water again.
• Set the Loss of Prime alarm characteristics in P1-18, P1-19, P1-20, and P1-21.
• Drive response to this condition is controlled by P1-21, Loss of Prime Selection.

HOA Keypad Display

Minor Fault Name

LOSUC

Low Suction

Low Section Pressure

Cause

Possible Solution

The suction pressure has fallen below the

level set in Q5-09 for longer than the time

set in Q5-10. This is only effective when

Q5-11, Low Suction Pressure Behavior

Select is set to 1 (alarm).

• Increase the system pressure.
• Set the Low Suction fault characteristics in Q5-09, Q5-10, and Q5-18.
• Drive response to this condition is controlled by Q5-11, Low Suction Pressure Behavior Select.
• Auto-restart of this fault is controlled by Q5-11, Low Suction Pressure Behavior Select and Q5-15, Suction

Pressure Auto-restart Time.

HOA Keypad Display

Minor Fault Name

Low City Pressure

Low City Pressure

Cause

Possible Solution

Insufficient pressure is present on the inlet

to the pump.

• Check pressure switch contact for correct operation.
• Check control wiring to drive terminal strip from pressure switch contact.
• Check to make sure that suction pressure is present by means of a separate measuring device.

HOA Keypad Display

Minor Fault Name

Low Feedback Low FB Sensed

Low Feedback Level Alarm
The feedback signal is too low.

Cause

Possible Solutions

The feedback level has dropped below the

level set in P1-08, Low Feedback Level

This is only effective when P1-10, Low

Feedback Selection, is set to 1 (Alarm and

digital out).

• Increase the feedback signal.
• Set the Low Feedback alarm characteristics in P1-08 and P1-09.
• Drive response to this condition is controlled by P1-10, Low Feedback Selection.

HOA Keypad Display

Minor Fault Name

Low Suction Pressure

Low Suction Pressure

Cause

Possible Solution

Insufficient suction pressure is present.

This is only effective when Q5-11, Low

Suction Pressure Behavior Select is set to 1

(alarm).

• Check pressure switch contact for correct operation.
• Check control wiring to drive terminal strip from pressure switch contact.
• Check to make sure that suction pressure is present by means of a separate measuring device.
• Increase the system pressure.
• Set the Low Suction alarm characteristics in Q5-09, Q5-10, and Q5-18.
• Drive response to this condition is controlled by Q5-11, Low Suction Pressure Behavior Select.

HOA Keypad Display

Minor Fault Name

Low Water in Tank

Low Water in Tank

Cause

Possible Solution

The water level in the tank is too low. This

is only effective when Q4-11, Low Level

Behavior is set to 1 (alarm).

• Check pressure switch contact for correct operation.
• Check control wiring to drive terminal strip from pressure switch contact.
• Check to make sure that suction pressure is present by means of a separate measuring device.
• Raise the water level.
• Set the Low Water Level alarm characteristics in Q4-09 and Q4-10.
• Drive response to this condition is controlled by Q4-11, Low Level Behavior.