No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

P3-40

(0CEF)

Pre-Charge Lag Pump

Select

Precharge LagSel

0: Disabled

2: Pump2 (H2-0X=80)

3: Pump3 (H2-0X=81)

4: Pump4 (H2-0X=82)

5: Pump5 (H2-0X=83)

6: Pump6 (H2-0X=84)

Selects which of the lag pumps can come on during a pre-charge.

0: Disabled

2: Pump 2 (H2-0o = 80)

3: Pump 3 (H2-0o = 81)

4: Pump 4 (H2-0o = 82)

5: Pump 5 (H2-0o = 83)

6: Pump 6 (H2-0o = 84)

Default: 0

Range: 0; 2 to 6

P3-41

(0CF0)

Pre-Charge Lag Pump

Run Time

Precharge Lag Tm

Sets the length of time that the lag pump specified in P3-40 is

energized.

Default: 0.0 min

Min.: 0.0

Max.: 3600.0

P3-42

(0CF1)

Post-Pre-Charge Lag

Pump Operation

Post PreChg Lag

0: Turn Off

1: Continue

Determines whether the lag pump set in pre-charge (P3-40)

turns off or maintains its state when pre-charge is completed.

0: Turn off

1: Continue

Default: 0

Range: 0, 1

P3-43

(0CF2)

Pre-Charge Lag Pump

Delay Time

PreChg Lag Delay

Sets the length of time that the drive is in the pre-charge mode

before the lag pump set in P3-40 is energized.

Default: 2.0 min

Min.: 0.0

Max.: 600.0

P3-50

(0CF9) Pump 2 Frequency

Shutdown Level

P2 Shutdown Freq

Sets the level used for the multiplex pumping operation.

Parameter is active only when P3-02 is set to 0 or 2.

When P3-02 is set to 0 and a total of two pumps are running, the

last pump (Pump 2) that was brought online will be shut down

by opening the dedicated mult-function discrete output

(H2-0o = 80 to 84) when the output frequency falls below the

level set in this parameter for the time set in P3-09.

When P3-02 is set to 2 and a total of two pumps are running, the

last pump (Pump 2) that was brought online will be shut down

by opening the dedicated mult-function discrete output

(H2-0o = 80 to 84) when the delta feedback (setpoint minus

feedback) has exceeded the level programmed in this parameter

for the time set in P3-09.

Default: 40.0 Hz

Min.: 0.0

Max.: 400.0

229

P3-60

(11E5) Pump 3 Frequency

Shutdown Level

P3 Shutdown Freq

Sets the level used for the multiplex pumping operation.

Parameter is active only when P3-02 is set to 0 or 2.

Parameter function is similar to P3-50, except for Pump 3

instead of Pump 2.

Default: 40.0 Hz

Min.: 0.0

Max.: 400.0

229

P3-70

(11EF) Pump 4 Frequency

Shutdown Level

P4 Shutdown Freq

Sets the level used for the multiplex pumping operation.

Parameter is active only when P3-02 is set to 0 or 2.

Parameter function is similar to P3-50, except for Pump 4

instead of Pump 2.

Default: 40.0 Hz

Min.: 0.0

Max.: 400.0

229

P3-80

(11F9) Pump 5 Frequency

Shutdown Level

P5 Shutdown Freq

Sets the level used for the multiplex pumping operation.

Parameter is active only when P3-02 is set to 0 or 2.

Parameter function is similar to P3-50, except for Pump 5

instead of Pump 2.

Default: 40.0 Hz

Min.: 0.0

Max.: 400.0

P3-90

(1203)

Pump 6 Frequency

Shutdown Level

P6 Shutdown Freq

Sets the level used for the multiplex pumping operation.

Parameter is active only when P3-02 is set to 0 or 2.

Parameter function is similar to P3-50, except for Pump 6

instead of Pump 2.

Default: 40.0 Hz

Min.: 0.0

Max.: 400.0

<1> Unit is determined by P1-02, System Units, setting.
<2> Available in drive software versions PRG: 8551 and later.

u

P4: Pump Advanced

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

P4-01

(0CFA) Pre-Charge Level

Pre-Charge Level

Runs the drive at the frequency set in P4-02.

The drive will stop when one of the following conditions occurs:
• The feedback level rises above the level set in P4-01
• The pre-charge time set in P4-03 expires
• The low water digital input is deactivated (#8F)

Default: 0.0 PSI

<1>

Min.: 0.0

Max.: 6000.0

229

P4-02

(0CFB) Pre-Charge Frequency Pre-Charge Freq.

Sets the frequency reference used when the Pre-Charge function

is active.

Default: 0.0 Hz

Min.: 0.0

Max.: [E1-04]

229

B.11 P: Pump Parameters

YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide

379

B