Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 345

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

F6-51

(03C2)

DeviceNet

Communication Speed

DN Baud Rate

0: 125 kbps

1: 250 kbps

2: 500 kbps

3: Set from Network

4: Auto Detect

0: 125 kbps

1: 250 kbps

2: 500 kbps

3: Adjustable from network

4: Detect automatically

Default: 4

Range: 0 to 4

F6-52

(03C3) DeviceNet PCA Setting DN PCA Selection

Sets the format of the data set from the DeviceNet master to the

drive.

Default: 21

Min.: 0

Max.: 255

F6-53

(03C4) DeviceNet PPA Setting DN PPA Selection

Sets the format of the data set from the drive to the DeviceNet

master.

Default: 71

Min.: 0

Max.: 255

F6-54

(03C5)

DeviceNet Idle Mode

Fault Detection

DN Idle Flt Det

0: Stop

1: Ignore

0: Enabled

1: Disabled, no fault detection

Default: 0

Range: 0, 1

F6-55

(03C6)

DeviceNet Baud Rate

Monitor

DN BAUD RATE

MEM

0: 125 kbps

1: 250 kbps

2: 500 kbps

Verifies the baud rate running on the network.

0: 125 kbps

1: 250 kbps

2: 500 kbps

Default: 0

Range: 0 to 2

F6-56

(03D7)

DeviceNet Speed

Scaling

DN Speed Scale

Sets the scaling factor for the speed monitor in DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-57

(03D8)

DeviceNet Current

Scaling

DN Current Scale

Sets the scaling factor for the output current monitor in

DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-58

(03D9)

DeviceNet Torque

Scaling

DN Torque Scale

Sets the scaling factor for the torque monitor in DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-59

(03DA)

DeviceNet Power

Scaling

DN Power Scale

Sets the scaling factor for the power monitor in DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-60

(03DB)

DeviceNet Voltage

Scaling

DN Voltage Scale

Sets the scaling factor for the voltage monitor in DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-61

(03DC)

DeviceNet Time

Scaling

DN Time Scale

Sets the scaling factor for the time monitor in DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-62

(03DD)

DeviceNet Heartbeat

Interval

DN Heart Beat

Sets the heartbeat interval for DeviceNet communications.

Default: 0

Min.: 0

Max.: 10

F6-63

(03DE)

DeviceNet Network

MAC ID

DN MAC ID MEM

Saves and monitors settings 0 to 63 of F6-50 (DeviceNet MAC

Address).

Default: 63

Min.: 0

Max.: 63

F6-64 to

F6-71

(03DF to

03C8)

Dynamic I/O Assembly

Parameters

Dynamic I/O Assembly Parameters

F7-01

(03E5)

<2>

IP Address 1

IP Address 1

Sets the most significant octet of network static IP address.

Default: 192

Range: 0 to 255

F7-02

(03E6)

<2>

IP Address 2

IP Address 2

Sets the second most significant octet of network static IP

address.

Default: 168

Range: 0 to 255

F7-03

(03E7)

<2>

IP Address 3

IP Address 3

Sets the third most significant octet of network static IP address. Default: 1

Range: 0 to 255

F7-04

(03E8)

<2>

IP Address 4

IP Address 4

Sets the fourth most significant octet of network static IP

address.

Default: 20

Range: 0 to 255

F7-05

(03E9) Subnet Mask 1

Subnet Mask 1

Sets the most significant octet of network static Subnet Mask. Default: 255

Range: 0 to 255

B.6 F: Options

YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide

345

B

Parameter List

Advertising