No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

C4-06

(021A)

Torque Compensation

Primary Delay Time 2

Start Torq Time

OLV

OLV

OLV

OLV

Sets the torque compensation time 2.

Default: 150 ms

Min.: 0

Max.: 10000

u

C6: Carrier Frequency

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

C6-02

(0224)

Carrier Frequency

Selection

CarrierFreq Sel

1: 2.0 kHz

2: 5.0 kHz

3: 8.0 kHz

4: 10.0 kHz

5: 12.5 kHz

6: 15.0 kHz

7: Swing PWM1

8: Swing PWM2

9: Swing PWM3

A: Swing PWM4

F: Program

1: 2.0 kHz

2: 5.0 kHz (4.0 kHz)

3: 8.0 kHz (6.0 kHz)

4: 10.0 kHz (8.0 kHz)

5: 12.5 kHz (10.0 kHz)

6: 15.0 kHz (12.0 kHz)

7: Swing PWM1 (Audible sound 1)

8: Swing PWM2 (Audible sound 2)

9: Swing PWM3 (Audible sound 3)

A: Swing PWM4 (Audible sound 4)

B to E: No setting possible

F: User-defined (determined by C6-03 through C6-05)

Note:

The available settings are 1, 2, and F for models

4A0930 and 4A1200.

Default: 7

Range: 1 to 9;

A, F

C6-03

(0225)

Carrier Frequency

Upper Limit

CarrierFreq Max

Determines the upper and lower limits for the carrier frequency.

Carrier Frequency

E1-04

Max Output

Frequency

Output Frequency

× (C6-05) × K

Output

Frequency

C6-03

C6-04

Default: 2.0 kHz

Min.: 1.0
Max.: 15.0

<1>

C6-04

(0226)

Carrier Frequency

Lower Limit

CarrierFreq Min

Default: 2.0 kHz

Min.: 1.0
Max.: 15.0

<1>

C6-05

(0227)

Carrier Frequency

Proportional Gain

CarrierFreq Gain

Default: 0

Min.: 0

Max.: 99

<1> Upper limit is 5.0 kHz in models 4A0515 to 4A1200.