E2: motor 1 parameters – Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 341

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

E1-04

(0303)

Maximum Output

Frequency

Max Frequency

These parameters are only applicable when E1-03 is set to F.

To set linear V/f characteristics, set the same values for E1-07

and E1-09.

In this case, the setting for E1-08 will be disregarded. Ensure

that the four frequencies are set according to these rules:

E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04

Output Voltage (V)

Frequency (Hz)

E1-05
E1-12

E1-13

E1-08

E1-10

E1-09

E1-07 E1-06 E1-11 E1-04

Default: 60.0 Hz

Min.: 40.0

Max.: 400.0

E1-05

(0304)

Maximum Voltage

Max Voltage

Default: 230 V

<1>

Min.: 0.0
Max.: 255.0

<1>

E1-06

(0305)

Base Frequency

Base Frequency

Default: 60.0 Hz

Min.: 0.0

Max.: E1-04

E1-07

(0306)

Middle Output

Frequency

Mid Frequency A

Default: 3.0 Hz

Min.: 0.0

Max.: E1-04

E1-08

(0307)

Middle Output

Frequency Voltage

Mid Voltage A

Default: 15.0 V

<1>

Min.: 0.0
Max.: 255.0

<1>

E1-09

(0308)

Minimum Output

Frequency

Min Frequency

Default: 1.5 Hz

(V/f)

0.5 Hz (OLV)

Min.: 0.0

Max.: E1-04

E1-10

(0309)

Minimum Output

Frequency Voltage

Min Voltage

Default: 9.0 V

(V/f)
2.0 V (OLV)

<1>

Min.: 0.0
Max.: 255.0

<1>

E1-11

(030A)

<4>

Middle Output

Frequency 2

Mid Frequency B

Default: 0.0 Hz

Min.: 0.0

Max.: E1-04

E1-12

(030B)

<4>

Middle Output

Frequency Voltage 2

Mid Voltage B

Default: 0.0 V

Min.: 0.0
Max.: 255.0

<1>

E1-13

(030C) Base Voltage

Base Voltage

Default: 0.0 V

<3>

Min.: 0.0
Max.: 255.0

<1>

<1> Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives.
<2> Parameter setting value is not reset to the default value when the drive is initialized.
<3> When Auto-Tuning is performed, E1-13 and E1-05 will be set to the same value.
<4> Parameter ignored when E1-11 (Motor 1 Mid Output Frequency 2) and E1-12 (Motor 1 Mid Output Frequency Voltage 2) are set to 0.0.

u

E2: Motor 1 Parameters

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

E2-01

(30E)

Motor Rated Current

Motor Rated FLA

Sets the motor nameplate full load current in amps.

Automatically set during Auto-Tuning.

Default:

<1>

Min.: 10% of

drive rated

current

Max.: 200% of

drive rated
current

<2>

216

E2-02

(030F) Motor Rated Slip

Motor Rated Slip

Sets the motor rated slip. Automatically set during Auto-Tuning. Default:

<1>

Min.: 0.00 Hz

Max.: 20.00 Hz

E2-03

(0310)

Motor No-Load Current No-Load Current

Sets the no-load current for the motor. Automatically set during

Auto-Tuning.

Default:

<1>

Min.: 0 A
Max.: E2-01

<2>

B.5 E: Motor Parameters

YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide