S6: protection – Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 399

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

S3-16

(3229)

Secondary PI High

Feedback Detection

Time

PI2 High FB Tim

Sets the secondary PI high feedback detection delay time in

seconds.

Default: 1.0 s

Min.: 0.0

Max.: 25.5

S3-17

(322A) Secondary PI Feedback

Detection Selection

PI2 FB Det Sel

0: PI2 Enabled

1: Always

Selects when secondary PI controller low and high feedback

detection are active.

0: Secondary PI enabled

1: Always

Default: 0

Range: 0, 1

<1> Unit is determined by S3-04.
<2> Upper limit is S3-02, decimal placeholder is determined by S3-03.

u

S6: Protection

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

S6-01

(3236)

Emergency Override

Speed

E Override Speed

Sets the speed command used in emergency override mode

when S6-02 = 0.

Default: 0.00 Hz

Min.: 0.00

Max.: 240.00

S6-02

(3237)

Emergency Override

Reference Selection

E OverrideRefSel

0: Use S6-01 Ref

1: Use Freq Ref

Selects the emergency override speed source.

0: Use S6-01 Reference

1: Use Frequency Reference

Default: 0

Range: 0, 1

S6-07

(323C)

Output Phase Loss

Level for Dynamic

Noise Control

DNC Outp Ph Loss

Reduces the output phase loss level when Dynamic Noise

Control is active.

Default: 100.0%

Min.: 10.0

Max.: 100.0

B.13 S: Special Application

YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide

399

B

Parameter List

Advertising