Alarm register contents, For alarm codes – Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 442

Advertising
background image

Fault Code

Fault Name

0233H

Sumcheck Error (oFb32)

0234H

Comm. option Timeout Waiting for Response (oFb33)

0235H

MEMOBUS Timeout (oFb34)

0236H

Drive Timeout Waiting for Response (oFb35)

0237H

CI Check Error (oFb36)

0238H

Drive Timeout Waiting for Response (oFb37)

0239H

Control Command Selection Error (oFb38)

023AH

Drive Timeout Waiting for Response (oFb39)

023BH

Control Response Selection 1 Error (oFb40)

023CH

Drive Timeout Waiting for Response (oFb41)

023DH

Control Response Selection 2 Error (oFb42)

023EH

Control Response Selection Error (oFb43)

0301H

Option Compatibility Error (oFC00)

0302H

Option Not Properly Connected (oFC01)

0303H

Same Type of Option Card Already Connected

(oFC02)

0306H

A/D Conversion Error (oFC05)

0307H

Option Response Error (oFC06)

0311H

Option RAM Fault (oFC10)

0312H

Option Operation Mode Fault (SLMOD) (oFC11)

0313H

Drive Receive CRC Error (oFC12)

Fault Code

Fault Name

0314H

Drive Receive Frame Error (oFC13)

0315H

Drive Receive Abort Error (oFC14)

0316H

Option Receive CRC Error (oFC15)

0317H

Option Receive Frame Error (oFC16)

0318H

Option Receive Abort Error (oFC17)

0331H

Comm. ID Error (oFC30)

0332H

Model Code Error (oFC31)

0333H

Sumcheck Error (oFC32)

0334H

Comm. Option Timeout Waiting for Response

(oFC33)

0335H

MEMOBUS Timeout (oFC34)

0336H

Drive Timeout Waiting for Response (oFC35)

0337H

CI Check Error (oFC36)

0338H

Drive Timeout Waiting for Response (oFC37)

0339H

Control Command Selection Error (oFC38)

033AH

Drive Timeout Waiting for Response (oFC39)

033BH

Control Response Selection 1 Error (oFC40)

033CH

Drive Timeout Waiting for Response (oFC41)

033DH

Control Response Selection 2 Error (oFC42)

033EH

Control Response Selection Error (oFC43)

u

Alarm Register Contents

The table below shows the alarm codes that can be read out from MEMOBUS/Modbus register 007FH.

Table C.6 Alarm Register 007FH Contents

Fault Code

Fault Name

0001H

Undervoltage (Uv)

0002H

Overvoltage (ov)

0003H

Heatsink Overheat (oH)

0004H

Drive Overheat (oH2)

0005H

Overtorque 1 (oL3)

0006H

Overtorque 2 (oL4)

0007H

Run commands input error (EF)

0008H

Drive Baseblock (bb)

0009H

Pump Fault 3, input terminal S3 (EF3)

000AH

Pump Fault 4, input terminal S4 (EF4)

000BH

Pump Fault 5, input terminal S5 (EF5)

000CH

Pump Fault 6, input terminal S6 (EF6)

000DH

Pump Fault 7, input terminal S7 (EF7)

000EH

Pump Fault 8, input terminal S8 (EF8)

000FH

Cooling Fan Error (FAn)

0014H

MEMOBUS/Modbus Communication Error (CE)

0015H

Option Communication Error (bUS)

0016H

Serial Communication Transmission Error (CALL)

0017H

Motor Overload (oL1)

0018H

Drive Overload (oL2)

001AH

Option Card External Fault (EF0)

001BH

Motor Switch command input during run (rUn)

001DH

Serial Communication Transmission Error (CALL)

001EH

Undertorque Detection 1 (UL3)

Fault Code

Fault Name

001FH

Undertorque Detection 2 (UL4)

0020H

MEMOBUS/Modbus Test Mode Fault (SE)

0022H

Motor Overheat (oH3)

0027H

PID Feedback Loss (FbL)

0028H

PID Feedback Loss (FbH)

002AH

Drive Disabled (dnE)

0031H

SI-T3 Watchdog Error (E5)

0032H

SI-T3 Station Address Setting Error (AEr)

0033H

SI-T3 Comm. Cycle Setting Error (CyC)

0034H

High Current Alarm (HCA)

0035H

Cooling Fan Maintenance Time (LT-1)

0036H

Capacitor Maintenance Time (LT-2)

0038H

SI-S EEPROM Error (EEP)

0039H

Pump Fault (input terminal S1) (EF1)

003AH

Pump Fault (input terminal S2) (EF2)

003FH

PLC Alarm (PA1)

0040H

PLC Alarm (PA2)

0041H

Output Voltage Detection Fault (voF)

0042H

IGBT Maintenance Time (90%) (TrPC)

0043H

Soft Charge Bypass Relay Maintenance Time (LT-3)

0044H

IGBT Maintenance Time (50%) (LT-4)

0045H

Braking Transistor Overload (boL)

0046H

Low Flow (LOWFL)

0047H

Accum Level (ACCUM)

C.9 MEMOBUS/Modbus Data Table