Register No.

Contents

00E2H

oFC1x Contents (CN5-C)
bit 0

Option RAM Fault (oFC10)

bit 1

Option Operation Mode Fault (SLMOD) (oFC11)

bit 2

Drive Receive CRC Error (oFC12)

bit 3

Drive Receive Frame Error (oFC13)

bit 4

Drive Receive Abort Error (oFC14)

bit 5

Option Receive CRC Error (oFC15)

bit 6

Option Receive Frame Error (oFC16)

bit 7

Option Receive Abort Error (oFC17)

bit 8 to F

Reserved

00E3H, 00E4H

Reserved

00E5H

oFC3x Contents (CN5-C)
bit 0

Comm. ID Error (oFC30)

bit 1

Model Code Error (oFC31)

bit 2

Sumcheck Error (oFC32)

bit 3

Comm. option timeout waiting for response (oFC33)

bit 4

MEMOBUS Timeout (oFC34)

bit 5

Drive timeout waiting for response (oFC35)

bit 6

CI Check Error (oFC36)

bit 7

Drive timeout waiting for response (oFC37)

bit 8

Control Command Selection Error (oFC38)

bit 9

Drive timeout waiting for response (oFC39)

bit A

Control Response Selection 1 Error (oFC40)

bit B

Drive timeout waiting for response (oFC41)

bit C

Control Response Selection 2 Error (oFC42)

bit D

Control Response Selection Error (oFC43)

bit E, F

Reserved

00E6H to 00FFH

Reserved

<1> Parameter o1-03, Digital Operator Display Selection, determines the units.
<2> Display is in the following units:

2A0004 to 2A0040, 4A0002 to 4A0023, and 5A0007 to 5A0017: 0.01 A units.
2A0056 to 2A0415, 4A0031 to 4A0675, and 5A0022 to 5A0242: 0.1 A units.
4A0930 and 4A1200: 1 A units.

<3> Communication error contents are saved until the fault is reset.
<4> Set the number of motor poles to parameter E2-04.

C.9 MEMOBUS/Modbus Data Table