Flange type heat loss data – Yaskawa iQpump1000 AC Drive Quick Start User Manual
Page 82
n
Flange Type Heat Loss Data
Table 2.20 Models 2A0138, 4o0072, and 5A0041 and 5A0052
Drive Model
Voltage
Class
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc = 8 kHz)
Internal
External
Total
Internal
External
Total
2A0138
200
312
842
1154
250
662
912
28 (61.6)
Drive Model
Voltage
Class
Input Type
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc = 8 kHz)
Internal
External
Total
Internal
External
Total
4A0072
400
6-Pulse
265
605
870
217
484
701
27 (59.4)
4T0072
<1>
12-Pulse
244
588
832
206
477
683
24 (52.8)
<1> Refer to manual TOEP C710616 50 for information on 12-pulse models.
Drive Model
Voltage
Class
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc = 8 kHz)
Internal
External
Total
Internal
External
Total
5A0041
600
136
331
467
128
406
534
27 (59.4)
5A0052
166
428
594
161
527
688
27 (59.4)
2.2 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss