Flange type heat loss data – Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 82

Advertising
background image

n

Flange Type Heat Loss Data

Table 2.20 Models 2A0138, 4o0072, and 5A0041 and 5A0052

Drive Model

Voltage

Class

Heat Loss (W)

Wt. kg (lb)

ND (Fc = 2 kHz)

HD (Fc = 8 kHz)

Internal

External

Total

Internal

External

Total

2A0138

200

312

842

1154

250

662

912

28 (61.6)

Drive Model

Voltage

Class

Input Type

Heat Loss (W)

Wt. kg (lb)

ND (Fc = 2 kHz)

HD (Fc = 8 kHz)

Internal

External

Total

Internal

External

Total

4A0072

400

6-Pulse

265

605

870

217

484

701

27 (59.4)

4T0072

<1>

12-Pulse

244

588

832

206

477

683

24 (52.8)

<1> Refer to manual TOEP C710616 50 for information on 12-pulse models.

Drive Model

Voltage

Class

Heat Loss (W)

Wt. kg (lb)

ND (Fc = 2 kHz)

HD (Fc = 8 kHz)

Internal

External

Total

Internal

External

Total

5A0041

600

136

331

467

128

406

534

27 (59.4)

5A0052

166

428

594

161

527

688

27 (59.4)

2.2 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss