Fault detection, Fault displays, causes, and possible solutions, 2 fault detection – Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 241

Advertising
background image

5.2 Fault Detection

u

Fault Displays, Causes, and Possible Solutions

Faults are detected for drive protection, and cause the drive to stop while triggering the fault output terminal MA-MB-MC.

Remove the cause of the fault and manually clear the fault before attempting to run the drive again.

Table 5.2 Detailed Fault Displays, Causes, and Possible Solutions

HOA Keypad Display

Fault Name

ACCUM

Accum Level

Accumulated Level Fault
The total volume of water flow measured over time by the flow meter has exceeded the fault level setting.

Cause

Possible Solution

The accumulated level has exceeded the

values set in P6-11 to P6-14. This is only

effective when P6-15, Accumulated

Behavior is set to 2 (fault with manual

monitor reset) or 3 (fault with automatic

monitor reset.

Set the Accumulated Level fault characteristics in P6-11 to P6-14 and P6-16.

Drive response to this condition is controlled by P6-15, Accumulated Behavior.

Auto-restart of this fault is controlled by P6-15, Accumulated Behavior and P6-05, Flow Accumulation Reset.

HOA Keypad Display

Fault Name

AJF

Anti-Jam Fault

Anti-Jam Fault

Cause

Possible Solution

The drive was not able to clear debris from

the impeller in fewer than the number of

attempts set in P7-02. This is only effective

when P7-01, Anti-jam Operation is set to 1

(enabled).

• Check for proper pump operation. Remove debris from the pump impeller.
• Set the Anti-jam fault characteristics in P7-02 to P7-08.
• Drive response to this condition is controlled by P7-01, Anti-jam Operation Selection.

HOA Keypad Display

Fault Name

bAT

Digital Operator Battery Voltage Low

Cause

Possible Solution

The digital operator battery is low

Replace the digital operator battery.

HOA Keypad Display

Fault Name

boL

Braking Transistor Overload Fault
The braking transistor reached its overload level.

Cause

Possible Solution

The wrong braking resistor is installed

Select the correct braking resistor.

HOA Keypad Display

Fault Name

bUS

Option Communication Error
• The connection was lost after establishing initial communication.
• Only detected when the run command frequency reference is assigned to an option card.

Cause

Possible Solution

No signal was received from the PLC

• Check for faulty wiring.
• Correct the wiring.
• Check for disconnected cables and short circuits and repair as needed.

Faulty communications wiring or an

existing short circuit

Communication data error occurred due to

noise

• Check the various options available to minimize the effects of noise.
• Counteract noise in the control circuit, main circuit, and ground wiring.
• Ensure that other equipment such as switches or relays do not cause noise. Use surge absorbers if

necessary.

• Use only recommended cables or other shielded line. Ground the shield on the controller side or the drive

input power side.

• Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive power

supply input.

The option card is damaged

Replace the option card if there are no problems with the wiring and the error continues to occur.

The option card is not properly connected

to the drive

• The connector pins on the option card do not line up properly with the connector pins on the drive.
• Reinstall the option card.

5.2 Fault Detection

YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide

241

5

Troubleshooting

Advertising