Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 254

Advertising
background image

Improper parameters related to Speed

Search (including Speed Search after a

momentary power loss and after a fault

restart)

• Check the settings for Speed Search-related parameters.
• Enable Speed Search restart function (b3-19 greater than or equal to 1 to 10).
• Adjust the current level during Speed Search and the deceleration time (b3-02 and b3-03 respectively).
• Perform Stationary Auto-Tuning for line-to-line resistance and then set b3-14 to 1 to enable Speed

Estimation Speed Search.

Drive input power voltage is too high

• Check the voltage.
• Lower drive input power voltage within the limits listed in the specifications.

The braking transistor or braking resistor

are wired incorrectly

• Check braking transistor and braking resistor wiring for errors.
• Properly rewire the braking resistor device.

Drive fails to operate properly due to noise

interference

• Review the list of possible solutions provided for controlling noise.
• Review the section on handling noise interference and check the control circuit lines, main circuit lines,

and ground wiring.

Load inertia is set incorrectly

• Check the load inertia settings when using KEB, overvoltage suppression, or Stall Prevention during

deceleration.

• Adjust the load inertia ratio in L3-25 to better match the load.

Motor hunting occurs

• Adjust the parameters that control hunting.
• Set the gain for Hunting Prevention (n1-02).
• Adjust the AFR time constant (n2-02 and n2-03).

HOA Keypad Display

Fault Name

PF

Input Phase Loss
Drive input power has an open phase or has a large imbalance of voltage between phases. Detected when

L8-05 is set 1 (enabled).

Cause

Possible Solution

There is phase loss in the drive input power

• Check for wiring errors in the main circuit drive input power.
• Correct the wiring.

There is loose wiring in the drive input

power terminals

• Ensure the terminals are tightened properly.
• Apply the tightening torque as specified in this manual.

Refer to Main Circuit Wire Gauges and

Tightening Torque on page 134

for details.

There is excessive fluctuation in the drive

input power voltage

• Check the voltage from the drive input power.
• Review the possible solutions for stabilizing the drive input power.

There is poor balance between voltage

phases

Stabilize drive input power or disable phase loss detection.

The main circuit capacitors are worn out

• Check the maintenance time for the capacitors (U4-05).
• Replace the capacitor if U4-05 is greater than 90%. For instructions on replacing the capacitor, contact

Yaskawa or a Yaskawa representative.

Check for problems with the drive input power. If drive input power appears normal but the alarm continues

to occur, replace either the control board or the entire drive. For instructions on replacing the control board,

contact Yaskawa or a Yaskawa representative.

HOA Keypad Display

Fault Name

PoC

Pump Over Cycle

Cause

Possible Solution

The pump has exceeded the number of

cycles set in P2-10 in the time set in P2-11

and P2-12 is set to 2 (fault).

• Set the Pump Over Cycle fault characteristics in P2-10 and P2-11.
• Drive response to this condition is controlled by P2-12, Over Cycling Mode.
• Auto-restart of this fault is controlled by L5-52, Pump Over Cycle Fault Retry Selection.
• Set the Pump Over Cycle automatic setpoint compensation in P2-12, Over Cycling Mode, P2-13, Setpoint

Compensation, and P2-14, Maximum Setpoint Compensation.

HOA Keypad Display

Fault Name

rF

Braking Resistor Fault
The resistance of the braking resistor is too low.

Cause

Possible Solution

The proper braking resistor option has not

been installed

Select a braking resistor option that it fits the drive braking transistor specification.

A regenerative converter, regenerative unit,

or braking unit is being used

Set L8-55 to 0 to disable the braking transistor protection selection.

5.2 Fault Detection

254

YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide

Advertising