Flange Type Heat Loss Data

Table 2.24 Models 2A0169 and 2A0211, 4o0139 and 4o0165, and 5A0062 to 5A0099

Drive Model

Voltage

Class

Heat Loss (W)

Wt. kg (lb)

ND (Fc = 2 kHz)

HD (Fc =

<1>

)

Internal

External

Total

Internal

External

Total

2A0169

200

380

1014

1394

306

816

1122

41 (90.2)

2A0211

473

1218

1691

378

976

1354

42 (92.4)

<1> Carrier frequency is set to 8 kHz in model 2A0169 and set to 5 kHz in model 2A0211.

Drive Model

Voltage

Class

Input Type

Heat Loss (W)

Wt. kg (lb)

ND (Fc = 2 kHz)

HD (Fc =

<1>

)

Internal

External

Total

Internal

External

Total

4A0139

400

6-Pulse

534

1215

1749

416

908

1324

45 (99.0)

4A0165

668

1557

2225

580

1340

1920

46 (101.2)

4T0139

<2>

12-Pulse

487

1179

1666

447

1100

1547

39 (85.8)

4T0165

<2>

624

1520

2164

629

1647

2276

40 (88.2)

<1> Carrier frequency is set to 8 kHz in model 4o0139 and set to 5 kHz in model 4A0165.
<2> Refer to manual TOEP C710616 50 for information on 12-pulse models.

Drive Model

Voltage

Class

Heat Loss (W)

Wt. kg (lb)

ND (Fc = 2 kHz)

HD (Fc =

<1>

)

Internal

External

Total

Internal

External

Total

5A0062

600

279

791

1070

335

1272

1607

45 (99.0)

5A0077

329

959

1288

379

1457

1836

45 (99.0)

5A0099

412

1253

1665

352

1267

1619

45 (99.0)

<1> Carrier frequency is set to 8 kHz in models 5A0062 and 5A0077 and set to 5 kHz in model 5A0099.

2.2 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss