background image

The drive from which the parameters were copied

and the drive to which the parameters will be

written have different electrical specifications,

capacities, are set to different control modes, or are

different models.

Make sure model numbers and specifications are the same for both drives.

The device being used to write the parameters is

blank and does not have any parameters saved on

it.

Make sure all connections are correct, and copy the parameter settings onto the USB Copy Unit or

the HOA keypad.

HOA Keypad Display

Task

rdEr

Error Reading Data

Cause

Possible Solutions

Failed while attempting to read parameter settings

from the drive.

Press and hold the READ key on the USB Copy Unit for at least one second to have the unit read

parameters from the drive.

HOA Keypad Display

Task

rEAd

Reading Parameter Settings (flashing)

Cause

Possible Solutions

Displayed while the parameter settings are being

read onto the USB Copy Unit.

This is not an error.

HOA Keypad Display

Task

vAEr

Voltage Class, Capacity Mismatch

Cause

Possible Solutions

The drive from which the parameters were copied

and the drive on which the Verify mode is being

performed have different electrical specifications

or are a different capacity.

Make sure electrical specifications and capacities are the same for both drives.

HOA Keypad Display

Task

vFyE

Parameter settings in the drive and those saved to the copy function are not the same

Cause

Possible Solutions

Indicates that parameter settings that have been

Read and loaded onto the Copy Unit or HOA

keypad are different.

To synchronize parameters, either write the parameters saved on the USB Copy Unit or HOA keypad

onto the drive, or Read the parameter settings on the drive onto the USB Copy Unit.

HOA Keypad Display

Task

vrFy

Comparing Parameter Settings (flashing)

Cause

Possible Solutions

The Verify mode has confirmed that parameters

settings on the drive and parameters read to the

copy device are identical.

This is not an error.