Fault Name

UL4

Undertorque Detection 2
The current has fallen below the minimum value set for torque detection (L6-05) for longer than the allowable

time (L6-06).

Cause

Possible Solution

Parameter settings are not appropriate for

the load

Check L6-05 and L6-06 settings

There is a fault on the machine side

Check the load for any problems.

HOA Keypad Display

Fault Name

UL6

Motor Underload
The load has fallen below the underload curve defined in L6-14.

Cause

Possible Solution

The output current has fallen below the

motor underload curve defined in L6-14 for

longer than the time set to L6-03

Adjust the value set to L6-14 so that output current remains above the motor underload curve during normal

operation.

HOA Keypad Display

Fault Name

UnbC

<1>

Current Unbalance
Current flow has become unbalanced.

Cause

Possible Solution

The internal current sensor has detected a

current unbalance situation.

• Check wiring
• Check for damaged transistors.
• Check for short circuits or grounding problems on the connected motor.

<1> Detected in models 4A0930 and 4A1200.

HOA Keypad Display

Fault Name

Uv1

DC Bus Undervoltage
One of the following conditions occurred while the drive was running:
• Voltage in the DC bus fell below the undervoltage detection level (L2-05).
• For 200 V class drives: approximately 190 V
• For 400 V class drives: approximately 380 V (350 V when E1-01 is less than 400)
• For 600 V class drives: approximately 475 V
The fault is output only if L2-01 is set to 0 or 1 and the DC bus voltage has fallen below the level set to L2-05

for longer than the time set to L2-02.

Cause

Possible Solution

Input power phase loss

• The main circuit drive input power is wired incorrectly.
• Correct the wiring.

One of the drive input power wiring

terminals is loose

• Ensure there are no loose terminals.
• Apply the tightening torque specified in this manual to fasten the terminals.

Refer to Main Circuit Wire

Gauges and Tightening Torque on page 134

for details.

There is a problem with the voltage from

the drive input power

• Check the voltage.
• Correct the voltage to be within the range listed in drive input power specifications.
• If there is no problem with the power supply to the main circuit, check for problems with the main circuit

magnetic contactor.

The power has been interrupted

Correct the drive input power.

The main circuit capacitors are worn

• Check the maintenance time for the capacitors (U4-05).
• Replace either the control board or the entire drive if U4-05 exceeds 90%. For instructions on replacing

the control board, contact Yaskawa or a Yaskawa representative.

The relay or contactor on the soft-charge

bypass circuit is damaged

• Cycle power to the drive and see if the fault reoccurs.
• If the problem continues, replace either the control board or the entire drive. For instructions on replacing

the control board, contact Yaskawa or a Yaskawa representative.

• Check monitor U4-06 for the performance life of the soft-charge bypass.
• Replace either the control board or the entire drive if U4-06 exceeds 90%. For instructions on replacing

the control board, contact Yaskawa or a Yaskawa representative.

5.2 Fault Detection

YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide

257

5

Troubleshooting

Advertising