Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 263

Advertising
background image

HOA Keypad Display

Minor Fault Name

EF0

Option Card External Fault
An external fault condition is present.

Cause

Possible Solution

An external fault was received from the

PLC with F6-03 set to 3, which allows the

drive to continue running after an external

fault occurs.

• Remove the cause of the external fault.
• Remove the external fault input from the PLC.

There is a problem with the PLC program. Check the PLC program and correct problems.

HOA Keypad Display

Minor Fault Name

EF1

Pump Fault (Input Terminal S1)
External fault at multi-function input terminal S1.

EF2

Pump fault (input terminal S2)
External fault at multi-function input terminal S2.

EF3

Pump fault (input terminal S3)
External fault at multi-function input terminal S3.

EF4

Pump fault (input terminal S4)
External fault at multi-function input terminal S4.

EF5

Pump fault (input terminal S5)
External fault at multi-function input terminal S5.

EF6

Pump fault (input terminal S6)
External fault at multi-function input terminal S6.

EF7

Pump fault (input terminal S7)
External fault at multi-function input terminal S7.

EF8

Pump fault (input terminal S8)

External fault at multi-function input terminal S8.

Cause

Possible Solutions

An external device has tripped an alarm

function.

Remove the cause of the external fault and reset the multi-function input value.

Wiring is incorrect.

• Ensure the signal lines have been connected properly to the terminals assigned for external fault detection

(H1-oo = 2C to 2F).

• Reconnect the signal line.

Multi-function contact inputs are set

incorrectly.

• Check if the unused terminals have been set for H1-oo = 2C to 2F (External Fault).
• Change the terminal settings.

HOA Keypad Display

Minor Fault Name

EoF

Emergency Override Forward Run

Cause

Possible Solution

The multi-function digital input for

EmergOverrideFWD (H1-oo = AF) has

been closed.

Open H1-oo = AF if the emergency condition is no longer present

HOA Keypad Display

Minor Fault Name

Eor

Emergency Override Reverse Run

Cause

Possible Solution

The multi-function digital input for

EmergOverrideREV (H1-oo = B0) has

been closed.

Open H1-oo = B0 if the emergency condition is no longer present

HOA Keypad Display

Fault Name

E5

SI-T3 Watchdog Timer Error
The watchdog timed out.

Cause

Possible Solution

Data has not been received from the PLC Execute DISCONNECT or ALM_CLR, then issue a CONNECT command or SYNC_SET command and

proceed to phase 3. Refer to the SI-T3 Option Technical Manual for more details on troubleshooting.

5.3 Alarm Detection

YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide

263

5

Troubleshooting

Advertising