5.7 HOA Keypad Display Messages

Table 5.7

lists messages and errors that may appear during normal pump operation.

These messages do not trigger multi-function output terminals that have been set up to close when a fault or alarm occurs.

Table 5.7 HOA Keypad Display Messages

HOA Keypad Display

Description

Anti Jam Active

Displayed when the drive is performing the anti-jam function.

CrST

Cannot Reset

Fault reset was being executed when a Run command was entered. Ensure that a Run command cannot be entered

from the external terminals or option during fault reset. Turn off the Run command.

De-staging in X sec

Displayed during multiplexing when either a drive or contactor de-staging is in progress. X sec indicates the time

left before the de-staging takes place.

DigitalOut Delay Active

Displayed when the Digital Output Delay function is active.

Feedback Drop Check

Displayed when the drive is determining whether the feedback will change abruptly when the drive enters Sleep

Mode. Drop Level is configured by P2-08, Delta Sleep Feedback Drop Level, and P2-09 Feedback Detection

Drop Time.

Freq Reduction Active (P3-07)

Maximum Frequency temporarily reduced due to Staging.

LOCK

Parameter Locked

Displayed after an attempt to change a parameter when A1-01 = 3. Unlock the keypad by setting A1-01 = 2.

Lube Pump Active

Displayed when the the Lube Pump digital output is energized.

Net Geothm Tmp

Lost, Chk Source

Displayed when no valid analog Geothermal Temperature source can be found on the network.

Net Pump Err

Chk Faulted Pump

Displayed when the drive has been stopped because another drive in the network has a system fault or a Low City

Pressure alarm.

Net Start Delay

P9-29 Active

Displayed when the MEMOBUS network is waiting for the P9-29 timer to elapse.

Net Water Level

or Suction Lost

Displayed when the network source for Water Level or Suction Control Pressure has been lost.

Network FB Lost

Check FB Source

Displayed when no valid analog PI feedback source can be found on the network and network PI feedback has

been lost.

PASS

MEMOBUS/Modbus Comm. Test

Mode Complete

MEMOBUS/Modbus test has finished normally.

Pre Chg Mode

Exit in Xsec

Pre-charge 1 or 2 active. X indicates time left before pre-charge exits due to timers (P4-03 + P4-07).

Setpoint Boost Active (P3-11)

Maximum Frequency temporarily reduced due to Staging.

Single Phase Foldback

Displayed when an input phase has been lost, or when excess load is being drawn by the motor in a single phase

application.

Sleep Active

Min Suction Pres

Displayed when the drive has gone to sleep because the suction level has dropped below the level set in Q5-04

for longer than the time set in Q5-05.

Sleep Active

Min Water Level

Displayed when the drive has gone to sleep because the water level has dropped below the level set in Q4-04 for

longer than the time set in Q4-05.

Sleep Active Wait for Start

Displayed when the drive is in Sleep Mode or when the drive is waiting for the feedback level to reach the level

set in P1-04, Start Level.

Sleep Boost Active

Displayed when the drive entering Sleep Mode and the pressure setpoint is being boosted. During this time, the

U1-01, Frequency Reference, monitor will be updated with the boosted setpoint.

Staging in X sec

Displayed during multiplexing when either a drive or contactor staging is in progress. X sec indicates the time

left before the staging takes place.

Start Delay Adjust b1-11

Displayed when the drive start is being delayed by Coast to Stop with Timer (Back Spin Timer). This time is

adjusted by parameter b1-11, Coast to Stop with Timer Time.

Start Delay Timer Active

Displayed when the feedback level has reached the level set in P1-04, Start Level, and the Start Delay timer is

incrementing.

Thrust Mode

Thrust Active

Displayed during Thrust Mode.

Utility Delay Adjust by P4-17

Displayed when the drive is delaying the Run command due to the Utility Start Delay Function.