U6: operation status monitors, U7: case monitors, U9: operation status monitors – Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 410

Advertising
background image

u

U6: Operation Status Monitors

No.

(Addr.

Hex)

Name

LCD Display

Description

Analog

Output Level

Unit

U6-01

(0051)

Motor Secondary

Current (Iq)

Mot SEC Current

Displays the value of the motor secondary current (Iq). Motor

rated secondary current is 100%.

10 V: Motor

secondary rated

current

0.1%

U6-02

(0052)

Motor Excitation

Current (Id)

Mot EXC Current

OLV

OLV

OLV

OLV

Displays the value calculated for the motor excitation current

(Id). Motor rated secondary current is 100%.

10 V: Motor

secondary rated

current

0.1%

U6-05

(0059)

Output Voltage

Reference (Vq)

Voltage Ref (Vq)

OLV

OLV

OLV

OLV

Output voltage reference (Vq) for the q-Axis.

10 V: 200 Vrms

<1>

0.1 Vac

U6-06

(005A)

Output Voltage

Reference (Vd)

Voltage Ref (Vd)

OLV

OLV

OLV

OLV

Output voltage reference (Vd) for the d-Axis.

10 V: 200 Vrms

<1>

0.1 Vac

U6-07

(005F)

q-Axis ACR Output

ACR(q) Output

OLV

OLV

OLV

OLV

Displays the output value for current control relative to motor

secondary current (q-Axis).

10 V: 200 Vrms

<1>

0.1%

U6-08

(0060)

d-Axis ACR Output

ACR(d) Output

OLV

OLV

OLV

OLV

Displays the output value for current control relative to motor

secondary current (d-Axis).

110 V: 200
Vrms

<1>

0.1%

<1> Values shown are specific to 200 V class drives. Double the values for 400 V class drives. Multiply the values by 2.875 for 600 V class drives.

Note:

Fault histories are not kept when CPF00, CPF01, CPF06, CPF24, oFA00, oFb00, oFC00, Uv1, Uv2, or Uv3 occur.

u

U7: CASE Monitors

No.

(Addr.

Hex)

Name

LCD Display

Description

Analog

Output Level

Unit

U7-01

(0051)

CASE Software

Number

CASE Software #

Displays the CASE software version number.

No signal output

available

u

U9: Operation Status Monitors

No.

(Addr.

Hex)

Name

LCD Display

Description

Analog

Output Level

Unit

U9-01

(1901)

Network PI Feedback

Net PI Feedback

Displays the network PI feedback recognized by the iQpump

MEMOBUS network.

No signal output

available

Dep. on

P1-02

U9-02

(1902)

Network Activity

iQ Net Activity

Displays network traffic. A fluctuating number from 0 to 10000

denotes activity, while a relatively constant 0 denotes no

activity.

No signal output

available

<1>

U9-03

(1903)

Time to Alternate

Time to Alternate

Displays the time remaining before a drive requests the

alternation mode set in P9-04.

No signal output

available

min

U9-04

(1904)

Running Queue

Number

Running Queue No

Displays the position in the iQPump MEMOBUS Multiplex

running queue.

No signal output

available

<1> Unit changes based on network status.

<->: Drive cannot communicate to other drives
<+>: Drive is a node on a network
<M>: Drive is the master on an iQpump network.

B.15 U: Monitors