Yaskawa iQpump1000 AC Drive Quick Start User Manual

Page 432

Advertising
background image

Register No.

Contents

00C0H

Fault Contents 3
bit 1

Undervoltage (Uv1)

bit 2

Control Power Supply Undervoltage (Uv2)

bit 3

Soft Charge Circuit Fault (Uv3)

bit 4

IGBT Short Circuit (SC)

bit 5

Ground Fault (GF)

bit 6

Overcurrent (oC)

bit 7

Overvoltage (ov)

bit 8

Heatsink Overheat (oH)

bit 9

Heatsink Overheat (oH1)

bit A

Motor Overload (oL1)

bit B

Drive Overload (oL2)

bit C

Overtorque Detection 1 (oL3)

bit D

Overtorque Detection 2 (oL4)

bit E

Dynamic Braking Transistor Fault (rr)

bit F

Braking Resistor Overheat (rH)

00C1H

Fault Contents 4
bit 0

External Fault at input terminal S3 (EF3)

bit 1

External Fault at input terminal S4 (EF4)

bit 2

External Fault at input terminal S5 (EF5)

bit 3

External Fault at input terminal S6 (EF6)

bit 4

External Fault at input terminal S7 (EF7)

bit 5

External Fault at input terminal S8 (EF8)

bit 6

Cooling Fan Error (FAn)

bit 7 to 9

Reserved

bit A

Input Phase Loss (PF)

bit B

Output Phase Loss (LF)

bit C

Motor Overheat (PTC input) (oH3)

bit D

Digital Operator Connection Fault (oPr)

bit E

EEPROM Write Error (Err)

bit F

Motor Overheat Fault (PTC input) (oH4)

00C2H

Fault Contents 5
bit 0

MEMOBUS/Modbus Communication Error (CE)

bit 1

Option Communication Error (bUS)

bit 2 to 3

Reserved

bit 4

Control Fault (CF)

bit 5

Reserved

bit 6

Option External Fault (EF0)

bit 7

PID Feedback Loss (FbL)

bit 8

Undertorque Detection 1 (UL3)

bit 9

Undertorque Detection 2 (UL4)

bit A

High Slip Braking Overload (oL7)

bit B to E

Reserved

bit F

Hardware Fault (includes oFx)

C.9 MEMOBUS/Modbus Data Table

432

YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide

Advertising