Three-Phase 600 V Class Drive Models 5A0003 to 5A0032

Table A.7 Power Ratings (Three-Phase 600 V Class)

Item

Specification

Drive Models

5A0003

5A0004

5A0006

5A0009

5A0011

5A0017 5A0022 5A0027 5A0032

Maximum Applicable

Motor Capacity (HP)

<1>

ND Rating

2

3

5

7.5

10

15

20

25

30

Input

Input Current (A)

<2>

ND Rating

3.6

5.1

8.3

12

16

23

31

38

45

Rated Voltage

Rated Frequency

Three-phase 500 to 600 Vac 50/60 Hz

Allowable Voltage Fluctuation

-10 (-15) to +10%

Allowable Frequency

Fluctuation

±5%

Input Power

(kVA)

ND Rating

4.1

5.8

9.5

14

18

26

35

43

51

Output

Rated Output

Capacity (kVA)

<3>

ND Rating

<4>

2.7

3.9

6.1

9

11

17

22

27

32

Rated Output

Current (A)

ND Rating

<4>

2.7

3.9

6.1

9

11

17

22

27

32

Overload Tolerance

ND Rating: 120% of rated output current for 60 s

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

User-adjustable between 1 and 15 kHz

<4>

User-adjustable between 1 and 10 kHz

<4>

Maximum Output Voltage (V)

Three-phase 500 to 600 V (proportional to input voltage)

Maximum Output

Frequency (Hz)

400 Hz (user-set)

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.

<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring

connections, and power supply impedance.

<3> Rated motor capacity is calculated with a rated output voltage of 575 V.
<4> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings

raise the carrier frequency and require current derating.