Bestlogic™plus composition – Basler Electric BE1-11m User Manual

Page 248

Advertising
background image

236

9424200996 Rev L

BESTlogic

Plus Composition

There are three main groups of objects used for programming BESTlogicPlus. These groups are I/O,
Components, and Elements. For details on how these objects are used to program BESTlogicPlus, see
the paragraphs on Programming BESTlogicPlus.

I/O

This group contains Input Objects, Output Objects, Off-Page Objects, and Alarms. Input objects can be
logically connected to any logic block input. Output objects can be logically connected to any logic block
output. Table 81 lists the names and descriptions of the objects in the I/O group.

Table 81. I/O Group, Names and Descriptions

Name

Description

Symbol

Input Objects

Logic 0

Always false (Low). Double-click or right-click on the
object to change the fixed state from 0 to 1.

Logic 1

Always true (High). Double-click or right-click on the object
to change the fixed state from 1 to 0.

Physical Inputs
IN1 – IN7

True when Physical Input x is active.

Status Inputs
Alarm Reset

The Alarm Reset status input goes momentarily high
when the Major, Minor, and Logic alarms are cleared.

Status Inputs
CT Circuit 1 Current
Detected

The CT Circuit 1 Current Detected status input goes high
when ac current is greater than 5% of nominal.

Status Inputs
Target Reset

The Target Reset status input goes momentarily high
when the targets are cleared.

Status Inputs
Start Button

The Start Button status input goes momentarily high when
the Start button on the front panel is pressed to start the
motor.

Status Inputs
Stop Button

The Stop Button status input goes momentarily high when
the Stop button on the front panel is pressed to stop the
motor.

Output Objects

Physical Outputs
OUT1 – OUT8 and
OUTA

Physical Outputs 1 through 8 and A.

Off-Page Objects

Off-Page Output

Used in conjunction with the Off-Page Input to transform
an output on one logic page into an input on another logic
page. Outputs can be renamed by right-clicking and
selecting Rename Output. Right-clicking will also show
pages that the corresponding inputs can be found on.
Selecting the page will take you to that page.

Off-Page Input

Used in conjunction with the Off-Page Output to transform
an output on one logic page into an input on another logic
page. Inputs can be renamed by right-clicking and
selecting Rename Input. Right-clicking will also show
pages that the corresponding outputs can be found on.
Selecting the page will take you to that page.

Alarms

Logic Alarm

True when the Logic Alarm is true. Refer to the

Alarms

chapter for more information.

BESTlogic

Plus

BE1-11m

Advertising